6.3 Trouble shooting
TROUBLES
A - The pump does not deliver
CAUSE
CORRECTION
- Pumping level is to high
- Reduce the pumping level
- Weared-off lobes
- Change the lobes
- Clogged suction filter
- Clean the filter
B - Unstable delivery and vibrations of the pump
CAUSE
CORRECTION
- Air infiltration in the suchtion line
- Check the suction line
- Clogged suction filter
- Clean the filter
- To high r.p.m. of the pump
- Check the r.p.m. and keep them at prescribed values
- To high pressure on the outlet side
- Reduce the pressure losses by reducing the r.p.m.
- To narrow suction line
- Keep the line diameter at prescribed dimension
- Viscosity or density of pumped media is to high
- Reduce r.p.m.
C - Overheating of the pump
CAUSE
CORRECTION
- To high pressure on the outlet side
- Reduce the pressure losses by reducing the r.p.m.
- To high r.p.m. of the pump
- Check the r.p.m. and keep them at prescribed values
14
Содержание VL 14
Страница 2: ......
Страница 17: ...7 1 Spare parts VL7 16 26 57 56 58 38 39 26...
Страница 19: ...7 2 Spare parts VL14 18 57 56 58 48 26 39 40 42 48 26...
Страница 21: ...7 3 Spare parts VL20 20 17 44 56 15 54 53 11 52 11 24 1 1 40 55 2 58 57 48 26 26 48 59 39 40 42...
Страница 23: ...22 7 4 Spare parts VL27 15 56 55 57 44 45 47 56 30 55 52 36...