background image

13 

 

 

 

 

Dismiss the network 

According  to  your  actual  situation,  if  you  no  longer  need  to  control  the 

machine  through  the  mobile  phone,  you  can  forcibly  release  the  binding 

between the machine and the APP and the network. The specific operation 

is as follows: long press the “wind speed” button to hear the “Di” sound, 

the  network  is  successfully  solved.  At  this  time,  the  device  information 

originally  added  in  the  APP  software  is  automatically  eliminated.  If  you 

want to control the machine again with software, you can re-distribute the 

network as described above. 

Tips

 

1. If the distribution network fails, please check if your network signal is 
normal, whether the product has entered the distribution network setting, 
whether the machine is connected to another mobile phone, etc., find out 
the reason and re-distribute the network. 
2.  Due  to  the  continuous  update  of  the  software,  the  description  of  the 
above  distribution  network  may  not  be  the  same  as  the  software  display. 
Please refer to the actual software display. 

 
 
 

 
 
 
 
 
 
 
 
 
 

Содержание Perla II

Страница 1: ...Instruction Manual Dehumidifier Please keep this instruction manual for future potential usage...

Страница 2: ...ntial usage Page Warnings 1 Specification 2 Working principle 3 Working environment 4 Important Safety Measures 5 Body of machine 6 Operation Method 7 9 Wi Fi Instructions 10 13 Drainage 14 15 Mainten...

Страница 3: ...ust be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsort...

Страница 4: ...ity 25 L day Power input Amp DB 27o C RH 60 270W Compressor rotation Refrigerant R290 Working range 5 35o C Water tank capacity 4 1 L Low High Speed 160 200 m h Size WxDxH 355 x 254 x 593 mm N W 14 0...

Страница 5: ...r flows through the body of the evaporator and radiator and then the relative humidity of the room could be controlled the excessive moisture air flow through the evaporator the air will condenses int...

Страница 6: ...et the room humidity according to your requirements It could create a healthy and comfortable environment The machine usually be used in basement wine cellar storage and closet It also could be used i...

Страница 7: ...must be accorded to the rating label 7 Don t plug unplug the machine to open close it Use the control panel 8 Before move the machine you need to turn off it unplug and make the water tank empty 9 If...

Страница 8: ...6 Body of machine 1 Handle for whole machine 2 Control Panel 3 Air Outlet 4 Air Inlet 5 Frame of Filter 6 Drainage 7 Water Tank 8 Power wire 9 Handle of water tank 10 Caster...

Страница 9: ...on work press button to stop it then all indicators are off Note in case of long idle please pull the power plug off Timing function 1 When on work press button to show current timing repeat pressing...

Страница 10: ...hoice of airflow speed Press button to choose high or low airflow speed Corresponding Indicator lights show the corresponding airflow speed Setting swing optional When machine is on work press button...

Страница 11: ...ely can switch between air purification mode and dehumidification mode Clothes drying function The setting of clothes drying function when the machine is on work press button and set the dehumidificat...

Страница 12: ...APP Note data traffic will be generated under 2G 3G 4G network 2 Login APP Open the app log in for the first time enter the phone number get the verification code and fill in select Read and agree to...

Страница 13: ...click the power indicator flashes at a faster frequency select the WiFi network to which the device is connected enter the password and click Next to configure the network 6 Network access During the...

Страница 14: ...off for five seconds if it is in power off state the power indicator is off At the same time the APP prompts the network to be successful check the device name and click OK to confirm the entry to th...

Страница 15: ...APP software is automatically eliminated If you want to control the machine again with software you can re distribute the network as described above Tips 1 If the distribution network fails please ch...

Страница 16: ...again Indicator light is still lit and machine does not work if tank is not placed in correct position Continuous drainage optional When machine should work for long time please refer as below 1 Take...

Страница 17: ...nvalid and the humidity display window displays E1 After the coil temperature sensor returns to normal the machine works normally 2 Humidity sensor failure When the humidity sensor is detected the com...

Страница 18: ...carbon filters optional Cleaning 1 dust filter cleaning remove grid then take Fig 4 off dust filter from the back of machine fig 4 2 Let dust off by a vacuum cleaner or brush it gently If filter is t...

Страница 19: ...does not run for long time please do as follows 1 Turn off machine cut off power and sort out power cord 2 Pour out tank water and wipe it 3 Clean the filter 4 Cover up machine and place it in one po...

Страница 20: ...e indoor is lower than 5 Machine does not remove moisture Whether the filter is dusty or contaminated Whether Inlet or outlet is blocked Whether humidity indoor is too less Dehumidification effect is...

Страница 21: ...perature of heat exchanger rises suddenly leading to temporary strange smell or musty taste Machine echoes If machine used in a small room or a wooden floor room may echo At the start of operation mod...

Страница 22: ...he room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment...

Страница 23: ...le gas stoves and other heat sources Don t disassemble overhaul and modify the machine arbitrarily otherwise it will cause a machine malfunction or even bring harm to persons and properties To avoid d...

Страница 24: ...arly qualified persons in order to avoid a hazard Transportation marking and storage for units 1 Transport of equipment containing flammable refrigerants Compliance with the transport regulations 2 Ma...

Страница 25: ...AC250V 3 15A Appliance is filled with flammable gas R290 and the maximum charge of refrigerant is 65g GWP value of R290refrigerant is 3 Any repairs you need contact the nearest authorized Service Cen...

Страница 26: ...the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or i...

Страница 27: ...uately and are not obstructed c If an indirect refrigerating circuit is being used the secondary circuit shall be checked for the presence of refrigerant d Marking to the equipment continues to be vis...

Страница 28: ...iginal specification damage to seals incorrect fitting of glands etc Ensure that apparatus is mounted securely Ensure that seals or sealing materials have not degraded such that they no longer serve t...

Страница 29: ...be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas 25 maximum is confirmed Leak detection fluids are suitab...

Страница 30: ...procedures In addition to conventional charging procedures the following requirements shall be followed 1 Ensure that contamination of different refrigerants does not occur when using charging equipme...

Страница 31: ...o more than 80 volume liquid charge 9 Do not exceed the maximum working pressure of the cylinder even temporarily 10 When the cylinders have been filled correctly and the process completed make sure t...

Страница 32: ...igerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially not in cyl...