JA95-R03 INTERCONNECT WIRING NOTES
NOTES
ALL WIRE SIZE SHOULD BE 24 AWG MIN UNLESS OTHERWISE SPECIFIED. UNSHIELDED WIRE
SHOULD BE SELECTED PER FAA AC43.13-1B CHANGE 1 PARA 11-76 TO 11-78. WIRE TYPES
SHOULD BE IN ACCORDANCE WITH MIL-W-22759 AS DESCRIBED IN FAA AC43.13-1B CHANGE 1
PARA 11-85 AND 11-86 AND LISTED IN TABLE 11-11 OR 11-12. ALL SHIELDED CABLE SHOULD BE IN
ACCORDANCE WITH MIL-DTL-27500 (REVISION H OR LATER).
CONNECTION TO AIRFRAME GROUND SHOULD BE MADE WITH 20 AWG WIRE. LENGTH NOT TO
EXCEED 1 FT (0.3 M).
CABLE SHIELDS AT THE JA95-R03 CONNECTOR PINS SHOULD BE TERMINATED TO AIRFRAME
GROUND USING A TAG RING P/N: MS27741-5 OR EQUIVALENT.
CONNECTOR PIN HAS MORE THAN ONE FUNCTION. SEE THE OPTIONS SECTION OF THIS
DRAWING FOR ALTERNATE INTERCONNECT WIRING.
2
1.
3
4
CONNECTOR PIN LEGENDS
LEGEND
SPARE
INTERNAL CIRCUITS MAY EXIST AND MAY BE ACTIVATED FOR FUTURE USE. NO EXTERNAL
WIRE CONNECTION.
JUPITER AVIONICS TEMPLATE AUTOCAD PORTRAIT SIZEA REV B.DWT
TITLE
APPROVED
PREPARED
CHECKED
L00N3
NCAGE CODE
PART NO.
SHEET
DOC NO.
CONFIDENTIAL & PROPRIETARY
TO JUPITER AVIONICS CORP.
Audio Controller - Remote Mount - One Transceiver
Interconnect Notes
JA95-R03
1/6
JA95-R03 Interconnect Rev A.dwg
TAT
JAC
SRM
06-16-16
JAC
KDV
06-16-16