INDICATION
LED STATUS INDICATOR
EMERGENCY MODE
OFF
NORMAL MODE
STEADY GREEN
BATTERY DISCONNECTED
STEADY RED
BATTERY HIGH CHARGE
RED AND GREEN FLASHING
BATTERY FAILURE*
RED TWO-PULSE
15-MINUTE BATTERY DISCHARGE**
GREEN (TWO-PULSE)
LED FAILURE
RED (THREE-PULSE)
LAMP FAILURE
RED (FOUR-PULSE)
*Functions only after a 15-minute test.
**Every 30 days.
MANUAL TEST
Battery, LED and Lamp Test may be manually initiated by pressing the Manual Test
Switch. Once the Manual Test Switch is pressed, the unit is reset, and the date of
battery self-testing begins counting again.
Exit and Emergency Lighting
INSTALLATION INSTRUCTIONS
FOR THERMOPLASTIC LED EXIT/EMERGENCY LIGHT COMBO
WITH SIGN WITH SELF-DIAGNOSTICS – NXPC SERIES
IMPORTANT SAFEGUARDS:
When using electrical equipment, always adhere to basic safety precautions including the following:
WARRANTY
Juno Lighting Group warrants that its products are free from defects in material and workmanship. Juno Lighting Group’s obligation
is expressly limited to repair or replacement, without charge, at Juno Lighting Group’s factory after prior written return authorization
has been granted. This warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group’s
factory. This warranty is in lieu of all other warranties, expressed or implied, and without limiting the generality of the foregoing phrase,
excludes any implied warranty of merchantability. Also, there are no warranties which extend beyond the description of the product
on the company’s literature setting forth terms of sale.
Product Services Phone (888) 387-2212
1300 S. Wolf Rd • P.O. Box 5065 • Des Plaines, IL 60017-5065 • Phone: 800-323-5068 • www.junolightinggroup.com
© 2005 Juno Printed in USA Rev 08/05 P0086 pg 2 of 2
BAT
TRANSFORMER
WIRING DIAGRAM