background image

STRM 5000 NEBS Hardware Guide

26

S

ETTING

 U

P

 STRM S

OFTWARE

 

AND

 C

ONFIGURING

 N

ETWORK

 S

ETTINGS

Accessing STRM

To access the STRM interface:

Step 1

Open your Web browser.

Step 2

Log in to STRM:

https://<IP Address>

<IP Address> 

is the IP address of the STRM system.

 

The default values are:
Username

: admin

Password

: <root password>

<root password> 

is the new root password you set during the installation 

process.

Step 3

Click Login To STRM.
STRM includes a default license key that allows you to access the interface for five 
weeks. A window shows the expiry date of the temporary license key. For 
information on installing a permanent license key, see the 

STRM Administration 

Guide

Note: 

You will need a permanent license for the STRM appliance to upgrade to a 

higher version. If you have a temporary license, the upgrade will fail; re-run the 
installer to upgrade to a higher version.

Содержание STRM 5000

Страница 1: ...Networks Inc 1194 North Mathilda Avenue Sunnyvale CA 94089 USA 408 745 2000 www juniper net Part Number 530 032977 Security Threat Response Manager STRM 5000 Hardware Installation Guide NEBS Level 3 C...

Страница 2: ...ncy energy If it is not installed in accordance with NetScreen s installation instructions it may cause interference with radio and television reception This equipment has been tested and found to com...

Страница 3: ...Installing the Hardware 11 LED Behavior 12 Chassis Console Port Pinouts 12 Connecting a Laptop or Keyboard and a Monitor 13 PREPARING YOUR SYSTEM FOR STRM SOFTWARE INSTALATION STRM Components 15 Brows...

Страница 4: ...HARDWARE SPECIFICATIONS MAINTAINING AND SERVICING THE HARDWARE RAID Array 31 Power Supply 31 Cooling Fans 32 Fan Filter 33...

Страница 5: ...S Front Panel Ports 6 Table 4 STRM 5000 NEBS Back Panel Components 7 Table 5 Required Ports of STRM 9 Table 6 Ethernet Port LEDs 12 Table 7 RJ 45 Console Connector Pinout 12 Table 8 Network Hierarchy...

Страница 6: ......

Страница 7: ...Set the Date and Time Window 22 Figure 7 Time Zone Continent Window 23 Figure 8 Time Zone Region Window 24 Figure 9 Configure STRM Window 24 Figure 10 New Root Password Window 25 Figure 11 Confirm Ne...

Страница 8: ......

Страница 9: ...levels Each level has established requirements also known as the NEBS criteria The NEBS criteria ensures roboust reliable and cost effective equipment deployment The NEBS Level 3 certification guaran...

Страница 10: ...documentation to techpubs comments juniper net Include the following information with your comments Document title Page number Contacting Customer Support To help you resolve any issues that you may...

Страница 11: ...cts The STRM appliances use two drivers Security Information Management SIM and Security Event Management SEM for security analysis of external and internal threats SIM provides reporting and analysis...

Страница 12: ...STRM 5000 NEBS Hardware Guide 4 STRM OVERVIEW...

Страница 13: ...Panel Indicators The STRM 5000 NEBS appliance has a 2U rack mountable chassis with dual redundant DC supplies and an optional AC power supply 2U hot swappable dual redundant RAID10 array 12 GB of memo...

Страница 14: ...d Indicates that a fan power supply or temperature alarm has occurred LAN LEDs Left LED green Indicates that the link is active Right LED Indicates the link speed off 10 Mbps green 100 Mbps amber 1Gbp...

Страница 15: ...the system Table 4 describes the back panel features Figure 3 STRM 5000 NEBS Back Panel Table 4 STRM 5000 NEBS Back Panel Components Components Description Cooling fans Draws air through vents of the...

Страница 16: ...STRM 5000 NEBS Hardware Guide 8 HARDWARE OVERVIEW...

Страница 17: ...re storing data such as Consoles Event Processors or Flow Processors be equipped with an Uninterrupted Power Supply UPS We recommend that you install STRM on your LAN to ensure that it can communicate...

Страница 18: ...way Check if the bracket dimple is nested properly in the chassis dimple Insert a Philips head screwdriver through the outer hole on the bracket to mate with the screw Torque the screw to 8 10 lbf in...

Страница 19: ...ed when securing the STRM 5000 NEBS ground wire to the rack frame To install the STRM 5000 NEBS appliance Step 1 Place the shipping container on a flat surface and remove the hardware components with...

Страница 20: ...console connector pinout information Step 7 Push the power button on the rear panel The green LED below the power button turns on The STRM hard disk LED turns on whenever the appliance reads data fro...

Страница 21: ...top or keyboard and monitor Follow the appropriate step Connect a laptop to the RJ 45 serial port on the front panel of the appliance Connect a keyboard and monitor to their respective ports on the fr...

Страница 22: ...STRM 5000 NEBS Hardware Guide 14 INSTALLING AND CONNECTING THE STRM HARDWARE...

Страница 23: ...may exist in your deployment include Flow Processor The Flow Processor creates superflows aggregate flows before the flows reach the Classification Engine Classification Engine Analyzes flows to clas...

Страница 24: ...he event An offense is an event that has been processed through STRM using multiple inputs individual events and events combined with analyzed behavior and vulnerabilities The Magistrate prioritizes t...

Страница 25: ...y DNS server Optional Public IP address for networks using Network Address Translation NAT E mail server NTP server Console only or Time server Identifying Security Monitoring Devices and Flow Data So...

Страница 26: ...the message level you wish to log for example critical informational or debug No of Users indicates the maximum number of hosts and users using or being served by this device Network Location indicat...

Страница 27: ...ormation on defining servers within STRM If your network includes a large number of servers you can use CIDR or IP subnet addresses within the server networks category Table 10 Asset Identification Se...

Страница 28: ...STRM 5000 NEBS Hardware Guide 20 PREPARING YOUR SYSTEM FOR STRM SOFTWARE INSTALATION...

Страница 29: ...e sure to set Connect Using to the appropriate COM port of the serial connector and Bits per second to 9600 You must also set Stop Bits 1 Data bits 8 and Parity None Step 2 Power on the system and log...

Страница 30: ...lect one of the following tuning templates Enterprise Tunes properties for internal network activity University Tunes properties for education specific concerns ISP Tunes properties for Internet Servi...

Страница 31: ...right arrow keys select Next Press Enter c Go to Step 10 Step 10 To specify a time server a In the text field enter the time server name or IP address b Using the left or right arrow keys select Next...

Страница 32: ...he left or right arrow keys select Next Press the Enter key The Configure STRM window appears See Figure 10 Figure 10 Configure STRM Window Step 12 To configure the STRM network settings enter values...

Страница 33: ...e Tab key to move to the Next option Press Enter The New Root Password window appears See Figure 11 Figure 11 New Root Password Window Step 14 To configure the STRM root password a Type a new password...

Страница 34: ...the new root password you set during the installation process Step 3 Click Login To STRM STRM includes a default license key that allows you to access the interface for five weeks A window shows the...

Страница 35: ...Weight 53lbs 11oz Chassis Material 18 gauge 0 048 in Cold rolled steel Fans 6 x 80mm redundant hot swap Rack mountable Front and rear or mid mount Ports 1 console 2x RJ 45 10 100 1000 Intel 82574 2x R...

Страница 36: ...2 205 lbs dry air Humidity storage 5 95 non condensing Altitude operating 10000 maximum Altitude storage 40000 maximum Thermal Dissipation Dual power supplies std 374W 1276 BTU hr typical 447W 1525 BT...

Страница 37: ...STRM 5000 NEBS Hardware Guide 29...

Страница 38: ...STRM 5000 NEBS Hardware Guide 30 HARDWARE SPECIFICATIONS...

Страница 39: ...se data reliability and increased I O performance The key concepts in RAID are Mirroring copy data to more than one disk Striping split data across more than one disk Error correction redundant data s...

Страница 40: ...ving the power supply Cooling Fans The STRM 5000 NEBS appliance has three cooling fans that are hot swappable The fan should be replaced in not less than 5 years of accumulated use To replace the fan...

Страница 41: ...mulated use To replace the air inlet filter in STRM 5000 NEBS appliance Step 1 Unfasten the 2 thumbscrews on the left of the front access cover Step 2 Open the access door Step 3 Pull out the front ed...

Страница 42: ...STRM 5000 NEBS Hardware Guide 34 MAINTAINING AND SERVICING THE HARDWARE Step 8 Make sure the filter covers up the front panel holes Step 9 Close the access door and refasten the 2 thumbscrews...

Страница 43: ...STRM 5000 NEBS Hardware Guide Fan Filter 35...

Страница 44: ...STRM 5000 NEBS Hardware Guide 36 MAINTAINING AND SERVICING THE HARDWARE...

Отзывы: