background image

Index

„

59

Index

A

access, configuring administrative

..............................27

addresses, default IP

.....................................................25

admin name and password, changing

........................26

administrative access, configuring

..............................27

ALARM LED

....................................................................11

B

back-panel components

................................................13

basic configuration

........................................................26

before you begin

............................................................16

bgroups, configuring

.....................................................29

bindings, default port and zone

...................................25

bridge groups, configuring

............................................29

C

certifications

...................................................................47

components, device

......................................................13

configuration

admin name and password

...................................26

administrative access

.............................................27

basic steps

................................................................26

bridge group (bgroup)

.............................................29

date and time

..........................................................28

default routes

...........................................................29

DNS server

...............................................................28

hostname and domain name

................................28

management services

.............................................27

USB

...........................................................................12

connecting power

..........................................................18

D

date and time, configuring

...........................................28

default routes, configuring

............................................29

device

certifications

............................................................47

configuration

............................................................26

dimensions

...............................................................45

weight

.......................................................................45

device LEDs

....................................................................11

dimensions of device

....................................................45

DNS servers, configuring

..............................................28

E

electrical specifications

.................................................46

EMC certifications

..........................................................47

emissions certifications

.................................................47

environmental specifications

.......................................46

equipment racks, installing

...........................................16

F

faceplates, removing

.....................................................38

factory defaults, resetting to

.........................................32

H

HA LED

...........................................................................11

hostnames and domain names, configuring

..............28

I

immunity certifications

.................................................47

installation

before you begin

.....................................................16

connecting power

....................................................18

equipment racks

......................................................16

PIMs

..........................................................................40

IP addresses, default

......................................................25

L

LEDs

activity link on Ethernet ports

...............................12

dashboard

................................................................11

LAN ports

.................................................................12

M

management

Telnet

........................................................................24

WebUI

.......................................................................24

management services, configuring

..............................27

managing

through WebUI

..................................................31, 32

memory, upgrading

.......................................................41

P

PIM LEDs

........................................................................11

PIMs

installing

...................................................................40

removing

..................................................................39

port bindings, default

....................................................25

POWER LED

...................................................................11

power switch

..................................................................14

Содержание SSG140

Страница 1: ...er Networks Inc 1194 North Mathilda Avenue Sunnyvale CA 94089 USA 408 745 2000 www juniper net Part Number 530 015643 01 Revision 05 Security Products SSG 140 Hardware Installation and Configuration G...

Страница 2: ...ense The following information is for FCC compliance of Class B devices The equipment described in this manual generates and may radiate radio frequency energy If it is not installed in accordance wit...

Страница 3: ...ack Panel 13 Physical Interface Module Slots 13 Power Switch 14 AC Power Appliance Inlet 14 Fuse Cover 14 Chapter 2 Installing and Connecting the Device 15 Before You Begin 16 Installing Equipment 16...

Страница 4: ...e CLI Reset Command 31 Restarting the Device with the WebUI 32 Resetting the Device to Factory Defaults 32 Device Serial Number 33 unset all 33 Reset Pinhole Button 34 Chapter 4 Servicing the Device 3...

Страница 5: ...onfiguration instructions and examples in this document are based on the functionality of a device running ScreenOS 6 0 0 Your device might function differently depending on the ScreenOS version you a...

Страница 6: ...for the SSG 140 device Conventions This guide uses the conventions described in the following sections Web User Interface Conventions on page 6 Command Line Interface Conventions on page 7 Web User I...

Страница 7: ...tomer with an active J Care or JNASC support contract or are covered under warranty and need postsales technical support you can access our tools and resources online or open a case with JTAC JTAC pol...

Страница 8: ...juniper net company communities Open a case online in the CSC Case Manager http www juniper net customers cm To verify service entitlement by product serial number use our Serial Number Entitlement SN...

Страница 9: ...elements on the front panel of the SSG 140 device Port Descriptions on page 10 Device Status LEDs on page 11 Ethernet Port LEDs on page 12 Reset Pinhole on page 12 USB Port on page 12 POWER HA PIM1 PI...

Страница 10: ...ation of the port From left to right on the front panel the interface names for the ports are ethernet0 0 through ethernet0 9 For the default zone bindings for each Ethernet port see Default Device Se...

Страница 11: ...riptions Name Color Status Description POWER Green On steadily Power is functioning correctly Off Device is not receiving power STATUS Green Off Device is powered off or is starting up Blinking Normal...

Страница 12: ...ware between a USB storage device and the internal flash storage of the security device The USB ports support USB 1 1 and USB 2 0 specifications You can also log messages to a USB storage device For m...

Страница 13: ...nel Figure 4 Back Panel of an SSG 140 Device The following sections describe the elements on the back panel of the SSG 140 device Physical Interface Module Slots on page 13 Power Switch on page 14 AC...

Страница 14: ...nlet and Fuse Cover AC Power Appliance Inlet The AC power appliance inlet is located on the right side of the back panel as shown in Figure 5 You use the AC power appliance inlet to connect the SSG 14...

Страница 15: ...n page 16 Installing Equipment on page 16 Organizing Interface Cables on page 18 Connecting Power on page 18 Powering the Device On and Off on page 18 Connecting the Device to a Network on page 18 NOT...

Страница 16: ...frame that blocks the air vents on the sides of the chassis Ensure that enclosed racks have fans and louvered sides Correct these hazardous conditions before any installation moist or wet floors leaks...

Страница 17: ...es of the device lift the device then position it in the rack When correctly positioned the device sits level in the equipment rack 3 Align the bottom hole in each mounting bracket with a hole in each...

Страница 18: ...panel of the device Plug the other end into an AC power source Powering the Device On and Off To power on the SSG 140 device press the AC power switch on the rear panel to the on position ScreenOS sta...

Страница 19: ...is prebound to the Untrust security zone 4 Connect an RJ 45 cable from the Console port using the instructions provided in Using a Console Connection on page 22 for management access Figure 8 Basic Ca...

Страница 20: ...SSG 140 Series Hardware Installation and Configuration Guide 20 Connecting the Device to a Network...

Страница 21: ...tions on page 30 Verifying External Connectivity on page 31 Restarting the Device on page 31 Resetting the Device to Factory Defaults on page 32 NOTE After you configure the device and verify connecti...

Страница 22: ...must be on the same subnetwork as the device You can also access the WebUI through a secure server using Secure Sockets Layer SSL with secure HTTP HTTPS Telnet SSH Telnet and SSH are applications that...

Страница 23: ...for the login name and password enter netscreen at both the login and password prompts Use lowercase letters only The login and password fields are both case sensitive For information about configurin...

Страница 24: ...I homepage opens the device is ready to be configured See Basic Device Configuration on page 26 to complete the initial device configuration Using Telnet To use a Telnet connection the workstation mus...

Страница 25: ...ng a management service such as Telnet You can change the default IP address on the ethernet0 0 interface to match the addresses on your LAN The SSG 140 comes preconfigured with three bridge group bgr...

Страница 26: ...dge Group Interfaces on page 29 The examples in this section demonstrate how to establish initial network connectivity For advanced configuration information refer to the Concepts Examples ScreenOS Re...

Страница 27: ...o the ethernet0 0 interface The workstation must have an IP address in the 192 168 1 1 24 subnet To change the default interface IP address on the device WebUI Network Interfaces Edit for ethernet0 0...

Страница 28: ...resolving hostnames and IP addresses Devices access the configured DNS servers to resolve hostnames In ScreenOS you configure the IP addresses for the primary and secondary DNS servers and the time of...

Страница 29: ...ecified by the default route To configure the default route on the device WebUI Network Routing Destination New trust vr Enter the following then click OK Network Address Netmask 0 0 0 0 0 0 0 0 Gatew...

Страница 30: ...aces on physical interface modules PIMs refer to the PIM and Mini PIM Installation and Configuration Guide Basic Firewall Protections The devices are configured with a default policy that permits work...

Страница 31: ...isms volume of the Concepts Examples ScreenOS Reference Guide Verifying External Connectivity To verify that workstations in your network can access resources on the Internet start a browser from any...

Страница 32: ...in prompt 2 If you have not yet changed the default username and password enter netscreen at both the login and password prompts Use lowercase letters only The login and password fields are both case...

Страница 33: ...he following message appears Reconfirm Lost Password Reset If you continue the entire configuration of the device will be erased In addition a permanent counter will be incremented to signify that thi...

Страница 34: ...2 As soon as the Status LED blinks green release the pinhole button and wait two seconds 3 The device now waits for the second reset which confirms the operation Push the pinhole button again for four...

Страница 35: ...and wait two seconds 4 Push the pinhole button again for four to six seconds The message 2nd push has been confirmed appears 5 Continue to press the pinhole button until the device resets The system n...

Страница 36: ...SSG 140 Series Hardware Installation and Configuration Guide 36 Resetting the Device to Factory Defaults...

Страница 37: ...nt on an SSG 140 device you need the following tools and parts Electrostatic bag or antistatic mat Electrostatic discharge grounding wrist strap Flat tip screwdriver 1 8 inch Number 2 phillips screwdr...

Страница 38: ...e device 2 If the device is powered on switch off the power switch on the back of the device Verify that the POWER LED is off 3 Loosen the screws on each side of the faceplate as shown in Figure 10 On...

Страница 39: ...the correct PIM 5 Disconnect the cables from the PIM 6 If necessary arrange the cables to prevent them from dislodging or developing stress points 7 Loosen the captive screws on each side of the PIM...

Страница 40: ...tive screws using a 1 8 inch flat tip screwdriver On PIMs with long screws for handles tighten the captive screws using a number 2 phillips screwdriver 7 Insert the appropriate cables into the cable c...

Страница 41: ...wdriver to remove the screws securing the rack mount brackets to the sides of the unit four screws per side 5 Use the phillips screwdriver to remove the six countersunk screws located along the bottom...

Страница 42: ...that the tabs swivel away from it 11 Grip the long edge of the memory module and slide it out Set it aside Figure 13 Releasing and Removing the Memory Module 12 Insert the 512 MB memory module into t...

Страница 43: ...lier securing the top panel to the chassis 16 Use the screwdriver to replace and tighten the screws securing the rack mount brackets to the sides of the chassis 17 Replace the SSG 140 in the equipment...

Страница 44: ...ng the Fuse 3 Manually remove the fuse assembly from the device 4 To replace the fuse assembly enter the new fuse into the opening and slide it in until the fuse clicks into place 5 Replace the power...

Страница 45: ...rs on page 48 Physical Table 5 provides the physical specifications for the SSG 140 device Table 5 SSG 140 Physical Specifications Description Value Chassis dimensions 1 75 inches 4 4 cm high 17 5 inc...

Страница 46: ...140 Environmental Tolerance Item Specification AC input voltage Operating range 90 to 264 VAC AC input line frequency 50 or 60 Hz AC device current rating 1 8A Description Value Altitude No performan...

Страница 47: ...ustralia New Zealand VCCI Class B Japan BSMI Class B Taiwan EMC Immunity EN 55024 EN 61000 3 2 Power Line Harmonics EN 61000 3 3 Voltage Fluctuations and Flicker EN 61000 4 2 ESD EN 61000 4 3 Radiated...

Страница 48: ...15 RJ 45 Connector Pin Numbering Table 9 lists the pinouts of the RJ 45 connectors for the Console and AUX ports Table 9 Console and AUX RJ 45 Connector Pinouts Pin Name I O Description 1 RTS Out O R...

Страница 49: ...uts Table 11 lists the RJ 45 connector pinouts for the Gigabit Ethernet ports Table 11 Gigabit Ethernet RJ 45 Connector Pinout DB 9 Pin RJ 45 Pin Name I O Description 1 N C DCD Carrier Detect 2 3 RxD...

Страница 50: ...hich are not supplied with the PIM Table 12 describe the RJ 48 connector pinouts Table 12 RJ 48 Connector to RJ 48 Connector Straight Pinout CAUTION To maintain agency approvals use only properly cons...

Страница 51: ...nfigure the interfaces that are installed on your device This section describes the following ICW windows 1 Rapid Deployment Window on page 52 2 Administrator Login Window on page 52 3 Physical Ethern...

Страница 52: ...glet from option browse to the file location then click Next The configlet sets up the device for you If you want to bypass the configuration wizard and go directly to the WebUI select the last option...

Страница 53: ...o the Trust security zone Ethernet0 1 is bound to the DMZ security zone but is optional Ethernet0 2 is bound to the Untrust zone Figure 19 Physical Ethernet Interface Window After binding an interface...

Страница 54: ...criptions for Ethernet0 0 Interface Field Description Dynamic IP via DHCP Enables the device to receive an IP address for the Untrust zone interface from an ISP Dynamic IP via PPPoE Enables the device...

Страница 55: ...e this screen to configure an IP address and a netmask for the DMZ interface Figure 21 DMZ Interface IP Address Window 6 Trust Interface IP Address Window Use this screen to configure an IP address an...

Страница 56: ...cal Ethernet DHCP Interface Window Select Yes to enable your device to assign IP addresses to your wired network via DHCP Enter the IP address range that you want your device to assign to clients usin...

Страница 57: ...and change as needed Click Next to save restart the device and run the configuration Figure 24 Confirmation Window After the device restarts with the saved system configuration the WebUI login prompt...

Страница 58: ...SSG 140 Series Hardware Installation and Configuration Guide 58...

Страница 59: ...lt routes configuring 29 device certifications 47 configuration 26 dimensions 45 weight 45 device LEDs 11 dimensions of device 45 DNS servers configuring 28 E electrical specifications 46 EMC certific...

Страница 60: ...4 resetting to factory defaults 32 restarting the device 31 routes configuring default 29 S safety certifications 47 services configuring management 27 specifications electrical 46 environmental 46 ph...

Отзывы: