Table 20: QFX3500 Device Environmental Tolerances (continued)
Tolerance
Description
•
Normal operation ensured in temperature range of 32° F through 104° F (0° C through
40° C)
•
Short-term operation ensured in temperature range of 23° F through 131° F (–5° C
through 55° C)
NOTE:
As defined in NEBS GR-63-CORE, Issue 3, short-term events can be up to 96
hours in duration but not more than 15 days per year.
•
Nonoperating storage temperature in shipping container: –40° F through 158° F (–40° C
through 70° C)
Temperature
Designed to comply with Zone 4 earthquake requirements per NEBS GR-63-CORE, Issue
3.
Seismic
NOTE:
Install QFX Series devices only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
RELATED DOCUMENTATION
Clearance Requirements for Airflow and Hardware Maintenance for a QFX3500 Device | 125
Installing and Connecting a QFX3500 Device | 326
Environmental Requirements and Specifications for EX Series Switches
The switch must be installed in a rack or cabinet housed in a dry, clean, well-ventilated, and
temperature-controlled environment.
Ensure that these environmental guidelines are followed:
•
The site must be as dust-free as possible, because dust can clog air intake vents and filters, reducing the
efficiency of the switch cooling system.
•
Maintain ambient airflow for normal switch operation. If the airflow is blocked or restricted, or if the
intake air is too warm, the switch might overheat, leading to the switch temperature monitor shutting
down the switch to protect the hardware components.
103
Содержание QFX3500
Страница 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Страница 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Страница 229: ...205...
Страница 238: ...Unterminated Fiber Optic Cable Warning 214...
Страница 246: ...Restricted Access Warning 222...
Страница 249: ...225...
Страница 257: ...Jewelry Removal Warning 233...
Страница 260: ...Operating Temperature Warning 236...
Страница 271: ...DC Power Disconnection Warning 247...
Страница 275: ...DC Power Wiring Sequence Warning 251...
Страница 278: ...DC Power Wiring Terminations Warning 254...
Страница 408: ...Understanding Virtual Chassis Fabric Configuration 4 Understanding Virtual Chassis Fabric Components 384...
Страница 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Страница 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Страница 565: ...Table 105 System Information continued Description Field Inventory details 541...
Страница 602: ...6 PART Troubleshooting Restoring Junos OS 579 Returning Hardware 586 Alarms and System Log Messages 623...