Safety Warnings Summary

This is a summary of safety warnings. For a complete list of warnings, including translations, see the EX9204 documentation

at

https://www.juniper.net/documentation/product/en_US/ex9204

.

WARNING:

Failure to observe these safety warnings can result in personal injury or death.

Before removing or installing components of a switch, attach an ESD strap to an ESD point, and place the other end of

the strap around your bare wrist to avoid. Failure to use an ESD strap could result in damage to the switch.

Permit only trained and qualified personnel to install or replace switch components.

Perform only the procedures described in this quick start and the EX Series documentation. Other services must be

performed only by authorized service personnel.

Before installing the switch, read the planning instructions in the EX Series documentation to ensure that the site meets

power, environmental, and clearance requirements for the switch.

Before connecting the switch to a power source, read the installation instructions in the EX Series documentation.

For the cooling system to function properly, the airflow around the chassis must be unrestricted. Allow at least 6 in.

(15.2 cm) of clearance between side-cooled switches. Allow 2.8 in. (7 cm) between the side of the chassis and any

non-heat-producing surface such as a wall.

Installing the EX9204 switch without using a mechanical lift requires three persons to lift the switch onto the mounting

shelf. Before lifting the chassis, remove the components. To prevent injury, keep your back straight and lift with your

legs, not your back. Do not lift the chassis by the power supply handles.

Mount the switch at the bottom of the rack if it is the only unit in the rack. When mounting the switch in a partially

filled rack, mount the heaviest unit at the bottom of the rack and mount the others from bottom to top in order of

decreasing weight.

When you install the switch, always connect the ground wire first and disconnect it last.

Wire the DC power supply using the appropriate lugs. When connecting power, the proper wiring sequence is ground

to ground, +RTN to +RTN, then –48 V to –48 V. When disconnecting power, the proper wiring sequence is –48 V to

–48 V, +RTN to +RTN, then ground to ground.

If the rack has stabilizing devices, install them in the rack before mounting or servicing the switch in the rack.

Before installing or after removing an electrical component, always place it component-side up on an antistatic mat

placed on a flat, stable surface or in an antistatic bag.

Do not work on the switch or connect or disconnect cables during electrical storms.

Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches.

Metal objects heat up when connected to power and ground and can cause serious burns or become welded to the

terminals.

10

Содержание EX9204

Страница 1: ...t Switch you need One small mounting shelf and 22 mounting screws provided Phillips screwdrivers numbers 1 and 2 not provided 7 16 in 11 mm torque controlled driver or socket wrench not provided One mechanical lift optional not provided Electrostatic discharge ESD wrist strap with cable provided 2 5 mm flat blade screwdriver not provided Power cord with a plug appropriate for your geographical loc...

Страница 2: ...nting shelves is at 0 02 in 0 05 cm above a U division Mounting Shelf Distance Above U Division Holes X 2 00 in 5 1 cm 1 14 U 4 X 1 51 in 3 8 cm 0 86 U 3 X 0 88 in 2 2 cm 0 50 U 2 X 0 25 in 0 6 cm 0 14 U 1 1 If needed install cage nuts in the holes as specified in the table 2 On the back of each rack rail partially insert a mounting screw into the lowest hole specified in the table 3 Install the m...

Страница 3: ...e all the components from the chassis before mounting NOTE While mounting multiple units on a rack mount the heaviest unit at the bottom and mount the other units from the bottom to the top in decreasing weight order 1 Safely remove all components power supplies Switch Fabric SF module fan tray air filter and line cards from the chassis 2 Ensure that the rack is properly secured to the building in...

Страница 4: ... from the bottom Ensure that all the mounting screws on one side of the rack are aligned with the mounting screws on the opposite side and the chassis is level Tighten the screws 9 Reinstall the chassis components Ensure that all empty slots are covered with a blank panel before operating the switch Connect Power to the Switch IN THIS SECTION Connecting EX9204 to AC power 4 Connecting EX9204 to DC...

Страница 5: ...e a multimeter to verify the resistance of the 48 V and RTN DC cables to chassis ground Cable with large resistance indicating an open circuit to chassis ground is 48 V Cable with low resistance indicating a closed circuit to chassis ground is RTN CAUTION You must ensure that power connections maintain the proper polarity The power source cables might be labeled and to indicate their polarity Ther...

Страница 6: ...the DC power supply terminal studs NOTE The DC power supplies in PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A and the DC power supplies in PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B This configuration provides the commonly deployed A B feed redundancy for the system 7 Replace the clear plastic cover over the terminal studs on the facepl...

Страница 7: ...ed on Set these values in the console server or PC baud rate 9600 flow control none data 8 parity none stop bits 1 DCD state disregard For management console connect the CON port of the Routing Engine RE module to the PC using the RJ 45 to DB 9 serial port adapter For Out of Band management connect the ETHERNET port of the RE module to the PC using an RJ 45 cable 7 ...

Страница 8: ...f a clear text password 3 Configure the name of the host If the name includes spaces enclose the name in quotation marks edit root set system host name host name 4 Create a user account edit root set system login user name authentication plain text password New password password Retype new password password 5 Set the user account class to super user edit root set system login user user name class ...

Страница 9: ...lnet service at the edit system services hierarchy level edit root set system services telnet 11 Optional Configure additional properties by adding the necessary configuration statements 12 Commit the configuration and exit the configuration mode NOTE To reinstall Junos OS boot the switch from the removable media Do not insert the removable media during normal operations The switch does not operat...

Страница 10: ...he chassis and any non heat producing surface such as a wall Installing the EX9204 switch without using a mechanical lift requires three persons to lift the switch onto the mounting shelf Before lifting the chassis remove the components To prevent injury keep your back straight and lift with your legs not your back Do not lift the chassis by the power supply handles Mount the switch at the bottom ...

Страница 11: ... Junos are registered trademarks of Juniper Networks Inc in the United States and other countries All other trademarks service marks registered marks or registered service marks are the property of their respective owners Juniper Networks assumes no responsibility for any inaccuracies in this document Juniper Networks reserves the right to change modify transfer or otherwise revise this publicatio...

Отзывы: