6
EX4200 Specifications
Physical Specifications
• Backplane: 128 Gbps Virtual Chassis interconnect to combine
up to 10 units as a single logical device
• Uplink module options:
-
4-port GbE module with pluggable SFP optics
-
2-port 10 GbE module with pluggable XFP optics
-
Dual-mode 2-port 10 GbE SFP+ / 4-port GbE SFP module
with pluggable SFP+/SFP optics
Power Options
• Power supplies: Autosensing; 100-120 V / 200-240 V;
AC 320 W, 600 W and 930 W dual load-sharing hot-swappable
internal redundant power supplies
• DC power supply: 190 W DC, input voltage range 36 V - 72 V,
dual input feed, dual load-sharing hot-swappable internal
redundant power supplies
• Minimum number of PSUs required for fully loaded chassis:
1 per switch
Dimensions (W x H x D)
• 17.4
1
x 1.7
2
x 16.4
3
in (44.2
1
x 4.3
2
x 41.7
3
cm)
1
Desktop installation width noted above, rack-mount width is
17.5 in (44.5 cm)
2
Height: 1 RU
3
Depth with 320 W AC PSU and 190 W DC PSU noted above,
18.8 in (47.8 cm) with 600/930 W AC PSU
System Weight
• EX4200-24T with 320 W AC PSU: 16.5 lb (7.5 kg)
• EX4200-24P with 600 W AC PSU: 17.2 lb (7.8 kg)
• EX4200-48T with 320 W AC PSU: 17.1 lb (7.8 kg)
• EX4200-48P with 930 W AC PSU: 18.2 lb (8.3 kg)
• EX4200-24F with 320 W AC PSU: 16.1 lb (7.3 kg)
• EX4200-24T-DC with 190 W DC PSU: 16.5 lb (7.5 kg)
• EX4200-48T-DC with 190 W DC PSU: 17.1 lb (7.8 kg)
• EX4200-24F-DC with 190 W DC PSU: 16.1 lb (7.3 kg)
Environmental Ranges
• Operating temperature: 32° to 113° F (0° to 45° C)
• Storage temperature: -40° to 158° F (-40° to 70° C)
• Operating altitude: up to 10,000 ft (3,049 m)
• Non-operating altitude: up to 16,000 ft (4,877 m)
• Relative humidity operating: 10% to 85% (noncondensing)
• Relative humidity non-operating: 0% to 95% (noncondensing)
Cooling
• Field-replaceable fan tray with multiple blowers (3)
• Switch remains operational even if one blower fails
• Airflow: 20.3 cfm
Hardware Specifications
• Switching Engine Model: Store and forward
• DRAM – 1 GB with ECC
• Flash – 1 GB
• CPU – 1 GHz PowerPC CPU
• GbE port density per system:
-
24P/24T/24F: 28 (24 host ports + four-port GbE uplink
module)
-
48P/48T: 52 (48 host ports + four-port GbE uplink module)
• 10 GbE port density per system (all models): 2 (uplink module)
Optics
• 100 Mbps optic/connector type: LC SFP fiber supporting
100BASE-FX SFP (multimode), LX (single-mode) and
BX (single-strand)
• 10/100/1000BASE-T connector type: RJ-45
• GbE SFP optic/connector type: RJ-45 or LC SFP fiber supporting
1000BASE-T SFP, SX (multimode), LX (single-mode), LH/ZX
(single-mode) and BX (single strand)
• 10 GbE XFP optic/connector type: 10GE XFP LC connector,
SR (multimode), LR (single-mode), ER (single-mode) or
ZR (single-mode)
• 10 GbE SFP+ optic/connector type: 10GE SFP+ LC connector, SR
(multimode), LR (single-mode) and LRM (multimode)
EX4200-24P
EX4200-24F
EX4200-24T
EX4200-48T
EX4200-48P