EX4200 Specifications

Physical Specifications

•  Backplane: 128 Gbps Virtual Chassis interconnect to combine 

up to 10 units as a single logical device 

•  Uplink module options:

 

-

4-port GbE module with pluggable SFP optics

 

-

2-port 10 GbE module with pluggable XFP optics

 

-

Dual-mode 2-port 10 GbE SFP+ / 4-port GbE SFP module 
with pluggable SFP+/SFP optics

Power Options

•  Power supplies: Autosensing; 100-120 V / 200-240 V; 

AC 320 W, 600 W and 930 W dual load-sharing hot-swappable 
internal redundant power supplies

•  DC power supply: 190 W DC, input voltage range 36 V - 72 V, 

dual input feed, dual load-sharing hot-swappable internal 
redundant power supplies

•  Minimum number of PSUs required for fully loaded chassis:  

1 per switch

Dimensions (W x H x D)

•  17.4

1

 x 1.7

2

 x 16.4

3

 in (44.2

1

 x 4.3

2

 x 41.7

3

 cm)

 

Desktop installation width noted above, rack-mount width is 

 17.5 in (44.5 cm) 

 

Height: 1 RU

 

Depth with 320 W AC PSU and 190 W DC PSU noted above, 

 18.8 in (47.8 cm) with 600/930 W AC PSU

System Weight

•  EX4200-24T with 320 W AC PSU: 16.5 lb (7.5 kg)
•  EX4200-24P with 600 W AC PSU: 17.2 lb (7.8 kg)
•  EX4200-48T with 320 W AC PSU: 17.1 lb (7.8 kg)
•  EX4200-48P with 930 W AC PSU:  18.2 lb (8.3 kg)
•  EX4200-24F with 320 W AC PSU:  16.1 lb (7.3 kg)
•  EX4200-24T-DC with 190 W DC PSU: 16.5 lb (7.5 kg)
•  EX4200-48T-DC with 190 W DC PSU: 17.1 lb (7.8 kg)
•  EX4200-24F-DC with 190 W DC PSU:  16.1 lb (7.3 kg)

Environmental Ranges

•  Operating temperature: 32° to 113° F (0° to 45° C)
•  Storage temperature: -40° to 158° F (-40° to 70° C)
•  Operating altitude: up to 10,000 ft (3,049 m) 
•  Non-operating altitude: up to 16,000 ft (4,877 m)
•  Relative humidity operating: 10% to 85% (noncondensing) 
•  Relative humidity non-operating: 0% to 95% (noncondensing)

Cooling

•  Field-replaceable fan tray with multiple blowers (3)
•  Switch remains operational even if one blower fails
•  Airflow: 20.3 cfm

Hardware Specifications

•  Switching Engine Model: Store and forward
•  DRAM – 1 GB with ECC
•  Flash – 1 GB
•  CPU – 1 GHz PowerPC CPU
•  GbE port density per system:

 

-

 24P/24T/24F: 28 (24 host ports + four-port GbE uplink 
module)

 

-

48P/48T: 52 (48 host ports + four-port GbE uplink module)

•  10 GbE port density per system (all models): 2 (uplink module)

Optics

•  100 Mbps optic/connector type: LC SFP fiber supporting 

100BASE-FX SFP (multimode), LX (single-mode) and  
BX (single-strand)

•  10/100/1000BASE-T connector type: RJ-45
•  GbE SFP optic/connector type: RJ-45 or LC SFP fiber supporting 

1000BASE-T SFP, SX (multimode), LX (single-mode), LH/ZX 
(single-mode) and BX (single strand)

•  10 GbE XFP optic/connector type: 10GE XFP LC connector,  

SR (multimode), LR (single-mode), ER (single-mode) or  
ZR (single-mode)

•  10 GbE SFP+ optic/connector type: 10GE SFP+ LC connector, SR 

(multimode), LR (single-mode) and LRM (multimode)

EX4200-24P

EX4200-24F

EX4200-24T

EX4200-48T

EX4200-48P

Содержание EX 4200 24F

Страница 1: ...s 3 Power over Ethernet PoE delivering 15 4 watts on the first eight ports to support networked devices such as telephones video cameras and wireless LAN WLAN access points for low density converged networks Full PoE options delivering 15 4 watts on all 24 or 48 ports are also available making them ideal for high density IP telephony deployments Juniper Networks Virtual Chassis Technology Chassis ...

Страница 2: ...storing the switch to its default settings The LCD also displays a Virtual Chassis member switch s chassis slot number and Route Engine status for rapid identification and problem resolution Dual rear panel Virtual Chassis ports enable EX4200 switches to be interconnected over the 128 Gbps virtual backplane Switches deployed in close proximity such as wiring closets or top of rack data center appl...

Страница 3: ...ng overall system maintenance and management Individually the EX4200 offers a number of HA features that are typically associated with modular chassis based switches When combined with the field proven Junos OS and L2 L3 failover capabilities these features provide the EX4200 with true carrier class reliability Figure 2 Support for Graceful Route Engine Switchover GRES ensures a smooth and seamles...

Страница 4: ...nabled devices the EX4200 delivers a future proofed solution for converging disparate networks onto a single IP infrastructure To ease deployment the EX4200 supports the industry standard Link Layer Discovery Protocol LLDP and LLDP Media Endpoint Discovery LLDP MED which enable the switches to automatically discover Ethernet enabled devices determine their power requirements and assign virtual LAN...

Страница 5: ...pply them through the command line interface CLI J Web interface or management system Four system management options are available for the EX4200 The standard Junos OS CLI management interface offers the same granular capabilities and scripting parameters found in any device powered by Junos OS The EX4200 also includes the integrated J Web management tool an embedded device manager that allows use...

Страница 6: ...5 lb 7 5 kg EX4200 48T DC with 190 W DC PSU 17 1 lb 7 8 kg EX4200 24F DC with 190 W DC PSU 16 1 lb 7 3 kg Environmental Ranges Operating temperature 32 to 113 F 0 to 45 C Storage temperature 40 to 158 F 40 to 70 C Operating altitude up to 10 000 ft 3 049 m Non operating altitude up to 16 000 ft 4 877 m Relative humidity operating 10 to 85 noncondensing Relative humidity non operating 0 to 95 nonco...

Страница 7: ... ARP entries 16 000 Max number of IPv4 unicast routes in hardware 10 000 Max number of IPv4 multicast routes in hardware 2 000 Routing protocols RIPv1 v2 OSPF BGP IS IS Static routing Routing policy Bidirectional Forwarding Detection Layer 3 redundancy VRRP Layer 3 Features IPv6 Max number of Neighbor Discovery ND entries 16 000 shared with IPv4 Max number of IPv6 unicast routes in hardware 1 000 ...

Страница 8: ...erv Assured Forwarding AF RFC 2475 DiffServ Core and Edge Router Functions LLDP Media Endpoint Discovery LLDP MED ANSI TIA 1057 draft 08 Draft ietf idr restart 10 txt Graceful Restart Mechanism for BGP Draft ietf isis restart 02 Restart Signaling for IS IS PIM DM Draft IETF PIM Dense Mode draft ietf idmr pim dm 05 txt draft ietf pim dm new v2 04 txt Draft ietf isis wg multi topology 11 Multi Topol...

Страница 9: ...icit Weighted Round Robin SDWRR 802 1p DSCP IP Precedence trust and marking Layer 2 4 classification criteria Interface MAC address Ethertype 802 1p VLAN IP address DSCP IP Precedence TCP UDP port numbers etc Congestion avoidance capabilities Tail Drop Multicast IGMP v1 v2 v3 IGMP snooping PIM SM IPv4 Multicast hardware entries 2 000 Services and Manageability Junos OS CLI Web interface Out of ban...

Страница 10: ...ietf idmr pim mib 09 Draft ietf bfd mib 02 txt Troubleshooting Debugging CLI via console Telnet or SSH Diagnostics Show and debug cmd statistics Traffic mirroring port Traffic mirroring VLAN ACL based mirroring Mirroring destination ports per system 1 LAG port monitoring Troubleshooting continued Multiple destination ports monitored to 1 mirror N 1 Max number of mirroring sessions 1 Mirroring to r...

Страница 11: ...4200 24T DC EX 4200 24P EX 4200 24F and EX 4200 24F DC switches EX 48 AFL Advanced Feature License for EX 4200 48T EX 4200 48T DC and EX 4200 48P switches MODEL NUMBER DESCRIPTION Uplink Modules EX UM 2XFP 2 port 10GbE XFP Uplink Module EX UM 4SFP 4 port GbE SFP Uplink Module EX UM 2X4SFP 2 port 10G SFP 4 port 1G SFP Uplink Module Each switch comes with one power supply RJ 45 cable RJ 45 to DB 9 s...

Страница 12: ...408 745 2000 Fax 408 745 2100 www juniper net To purchase Juniper Networks solutions please contact your Juniper Networks representative at 1 866 298 6428 or authorized reseller Printed on recycled paper MODEL NUMBER DESCRIPTION Pluggable Optics continued EX XFP 10GE SR XFP 10GBASE SR LC connector 850nm 300m reach on 50 microns multimode fiber 33m on 62 5 microns multimode fiber EX XFP 10GE ER XFP...

Отзывы: