Working as an enforcement point within the UAC, the EX4200 
provides both standards-based 802.1X port-level access 
control as well as Layer 2–4 policy enforcement based on user 
identity, location and/or device. A user’s identity, device type, 
machine posture check and location can be used to determine 
whether access should be granted and for how long. If access is 
granted, the switch assigns the user to a specific VLAN based on 
authorization levels. The switch can also apply QoS policies or 
mirror user traffic to a central location for logging, monitoring or 
threat detection by intrusion prevention systems.

The EX4200 also provides a full complement of port security 
features including DHCP (Dynamic Host Configuration Protocol) 
snooping, DAI (dynamic ARP inspection) and MAC limiting to 
defend against internal and external spoofing, man-in-the-middle 
and denial-of-service (DoS) attacks.

Simplified Management and Operations

When employing Virtual Chassis technology, the EX4200 
dramatically simplifies network management. Up to 10 
interconnected EX4200 switches can be managed as a single 
device. Each Virtual Chassis group utilizes a single Junos OS image 
file and a single configuration file, reducing the overall number 
of units to monitor and manage. When Junos OS is upgraded on 
the master switch in a Virtual Chassis configuration, the software 
is automatically upgraded on all other member switches at the 
same time. 

The EX4200 also includes port profiles that allow network 
administrators to automatically configure ports with security, QoS 
and other parameters based on the type of device connected 

to the port. Six preconfigured profiles are available, including 
default, desktop, desktop plus IP phone, wireless access point, 
routed uplink and Layer 2 uplink. Users can select from the existing 
profiles or create their own and apply them through the command 
line interface (CLI), J-Web interface or management system.

Four system management options are available for the EX4200. 
The standard Junos OS CLI management interface offers the same 
granular capabilities and scripting parameters found in any device 
powered by Junos OS. The EX4200 also includes the integrated 
J-Web management tool, an embedded device manager that 
allows users to configure, monitor, troubleshoot and perform 
system maintenance on individual switches via a browser-based 
graphical interface. 

When managing a group of EX4200 switches, the Juniper 
Networks Network and Security Manager (NSM) provides system-
level management across all Juniper switches in the network, from 
a single console.

Finally, the EX4200 switch system, performance and fault data can 
be exported to leading third-party management systems such as HP 
OpenView, IBM Tivoli and Computer Associates Unicenter software, 
to provide a complete, consolidated view of network operations.

Limited Lifetime Warranty

The EX4200 includes a limited lifetime hardware warranty that 
provides return-to-factory switch replacement for as long as the 
original purchaser owns the product. Power supplies and fan trays 
are covered for a period of five years. For complete details please 
visit

 www.juniper.net/support/warranty/.

Product Options

Eight EX4200 switch models are available (see Table 1 below).

Table 1: EX4200 Line of Ethernet Switches

MODEL

ACCESS PORT CONFIGURATION

POE PORTS*

HEIGHT

SYSTEM POWER (WITH POE)

EX4200-24T**

24-port 10/100/1000BASE-T

8

1 RU

190 W AC (320 W AC)

EX4200-24P

24-port 10/100/1000BASE-T

24

1 RU

190 W AC (600 W AC)

EX4200-48T**

48-port 10/100/1000BASE-T

8

1 RU

190 W AC (320 W AC)

EX4200-48P

48-port 10/100/1000BASE-T

48

1 RU

190 W AC (930 W AC)

EX4200-24F**

24-port 100/1000BASE-X (SFP)

N/A

1 RU

190 W AC

EX4200-24T-DC**

24-port 10/100/1000BASE-T

0

1 RU

190 W DC

EX4200-48T-DC**

48-port 10/100/1000BASE-T

0

1 RU

190 W DC

EX4200-24F-DC**

24-port 100/1000BASE-X (SFP)

N/A

1 RU

190 W DC

* All PoE ports 802.3af-compliant @ 15.4 W
** NEBS certified

Содержание EX 4200 24F

Страница 1: ...s 3 Power over Ethernet PoE delivering 15 4 watts on the first eight ports to support networked devices such as telephones video cameras and wireless LAN WLAN access points for low density converged networks Full PoE options delivering 15 4 watts on all 24 or 48 ports are also available making them ideal for high density IP telephony deployments Juniper Networks Virtual Chassis Technology Chassis ...

Страница 2: ...storing the switch to its default settings The LCD also displays a Virtual Chassis member switch s chassis slot number and Route Engine status for rapid identification and problem resolution Dual rear panel Virtual Chassis ports enable EX4200 switches to be interconnected over the 128 Gbps virtual backplane Switches deployed in close proximity such as wiring closets or top of rack data center appl...

Страница 3: ...ng overall system maintenance and management Individually the EX4200 offers a number of HA features that are typically associated with modular chassis based switches When combined with the field proven Junos OS and L2 L3 failover capabilities these features provide the EX4200 with true carrier class reliability Figure 2 Support for Graceful Route Engine Switchover GRES ensures a smooth and seamles...

Страница 4: ...nabled devices the EX4200 delivers a future proofed solution for converging disparate networks onto a single IP infrastructure To ease deployment the EX4200 supports the industry standard Link Layer Discovery Protocol LLDP and LLDP Media Endpoint Discovery LLDP MED which enable the switches to automatically discover Ethernet enabled devices determine their power requirements and assign virtual LAN...

Страница 5: ...pply them through the command line interface CLI J Web interface or management system Four system management options are available for the EX4200 The standard Junos OS CLI management interface offers the same granular capabilities and scripting parameters found in any device powered by Junos OS The EX4200 also includes the integrated J Web management tool an embedded device manager that allows use...

Страница 6: ...5 lb 7 5 kg EX4200 48T DC with 190 W DC PSU 17 1 lb 7 8 kg EX4200 24F DC with 190 W DC PSU 16 1 lb 7 3 kg Environmental Ranges Operating temperature 32 to 113 F 0 to 45 C Storage temperature 40 to 158 F 40 to 70 C Operating altitude up to 10 000 ft 3 049 m Non operating altitude up to 16 000 ft 4 877 m Relative humidity operating 10 to 85 noncondensing Relative humidity non operating 0 to 95 nonco...

Страница 7: ... ARP entries 16 000 Max number of IPv4 unicast routes in hardware 10 000 Max number of IPv4 multicast routes in hardware 2 000 Routing protocols RIPv1 v2 OSPF BGP IS IS Static routing Routing policy Bidirectional Forwarding Detection Layer 3 redundancy VRRP Layer 3 Features IPv6 Max number of Neighbor Discovery ND entries 16 000 shared with IPv4 Max number of IPv6 unicast routes in hardware 1 000 ...

Страница 8: ...erv Assured Forwarding AF RFC 2475 DiffServ Core and Edge Router Functions LLDP Media Endpoint Discovery LLDP MED ANSI TIA 1057 draft 08 Draft ietf idr restart 10 txt Graceful Restart Mechanism for BGP Draft ietf isis restart 02 Restart Signaling for IS IS PIM DM Draft IETF PIM Dense Mode draft ietf idmr pim dm 05 txt draft ietf pim dm new v2 04 txt Draft ietf isis wg multi topology 11 Multi Topol...

Страница 9: ...icit Weighted Round Robin SDWRR 802 1p DSCP IP Precedence trust and marking Layer 2 4 classification criteria Interface MAC address Ethertype 802 1p VLAN IP address DSCP IP Precedence TCP UDP port numbers etc Congestion avoidance capabilities Tail Drop Multicast IGMP v1 v2 v3 IGMP snooping PIM SM IPv4 Multicast hardware entries 2 000 Services and Manageability Junos OS CLI Web interface Out of ban...

Страница 10: ...ietf idmr pim mib 09 Draft ietf bfd mib 02 txt Troubleshooting Debugging CLI via console Telnet or SSH Diagnostics Show and debug cmd statistics Traffic mirroring port Traffic mirroring VLAN ACL based mirroring Mirroring destination ports per system 1 LAG port monitoring Troubleshooting continued Multiple destination ports monitored to 1 mirror N 1 Max number of mirroring sessions 1 Mirroring to r...

Страница 11: ...4200 24T DC EX 4200 24P EX 4200 24F and EX 4200 24F DC switches EX 48 AFL Advanced Feature License for EX 4200 48T EX 4200 48T DC and EX 4200 48P switches MODEL NUMBER DESCRIPTION Uplink Modules EX UM 2XFP 2 port 10GbE XFP Uplink Module EX UM 4SFP 4 port GbE SFP Uplink Module EX UM 2X4SFP 2 port 10G SFP 4 port 1G SFP Uplink Module Each switch comes with one power supply RJ 45 cable RJ 45 to DB 9 s...

Страница 12: ...408 745 2000 Fax 408 745 2100 www juniper net To purchase Juniper Networks solutions please contact your Juniper Networks representative at 1 866 298 6428 or authorized reseller Printed on recycled paper MODEL NUMBER DESCRIPTION Pluggable Optics continued EX XFP 10GE SR XFP 10GBASE SR LC connector 850nm 300m reach on 50 microns multimode fiber 33m on 62 5 microns multimode fiber EX XFP 10GE ER XFP...

Отзывы: