Fast Ethernet Cables
The Ethernet connection is a standard RJ-45 connector. Typically, a straight-through cable is used to
connect to a switch, and a crossover cable is used to connect to a router.
DC Power Cables
For CTP chassis with DC power options, we recommend 18-AWG power cables.
RELATED DOCUMENTATION
Required Tools, Wires, and Cables for the CTP2000 Platform | 109
Cabling the CTP Platform for DC Power | 111
Terminal Block and Circuit Breaker Specifications | 69
Terminal Block and Circuit Breaker Specifications
lists the electrical specifications for the terminal block (see
)
located on the back of the CTP2000 Series DC chassis.
Table 23: Terminal Block Electrical Specifications
Specification
Category
100 VDC
Voltage
20 A
Current
−55° through 105° C
Operating Temperature
Black thermoplastic or equivalent
Material
Minimum: 2500 pF
Maximum: 5200 pF
Capacitance
69
Содержание CTP2000 Series
Страница 1: ...CTP2000 Series Circuit to Packet Platforms Hardware Guide Published 2020 08 31 ...
Страница 8: ...1 PART Overview CTP2000 Series Platform Overview 2 CTP2000 Series Interface Modules 11 ...
Страница 112: ...Installing SFPs in a CTP2000 Module 102 105 ...
Страница 127: ...5 PART Configuration Accessing the CTP2000 Platform 121 ...
Страница 144: ...7 PART Troubleshooting Troubleshooting Power Failures 138 Contacting Customer Support 140 ...
Страница 149: ...Locating CTP Component Serial Numbers 141 Returning CTP Products for Repair or Replacement 136 142 ...