![JUNGLE HOBBIES LL-4800N Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/jungle-hobbies/ll-4800n/ll-4800n_quick-start-manual_2032081009.webp)
Saving function
The below functions can be saved whenever you want. Updated settings will
be automatically saved after 10 seconds of no operation.
Reset to factory settings
Press , then press to recover the default as below:
Smart Fan Cooling
The smart fan will automatically turn on when the temperature of the light reaches
approximately 38°C and turns off at approximately 34°C. The light will automatically
shut off and will display a warning of “ ” on the screen when its Temperature
reaches approximately 60°C.
6
7
8
Keys
Settings can be saved
Light on time
Dawn mode settings
Dawn mode settings
Sunrise
mode settings
Sunrise
mode settings
Daytime
mode settings
Daytime
mode settings
Sunset
mode settings
Sunset
mode settings
Nighttime
mode settings
Nighttime
mode settings
Temperature display
12/24-hour clock
The time duration of the dawn
The time duration of the nighttime
The time duration of the sunset
The time duration of the daytime
The time duration of the sunrise
The beginning time in a day
Lighting effects for the dawn
Lighting effects for the nighttime
Lighting effects for the sunset
Lighting effects for the daytime
Lighting effects for the sunrise
Celsius or Fahrenheit display
12-hour clock or 24-hour clock
Functions
05
:
00
02
:
00
01
:
00
10
:
00
02
:
00
03
:
00
Functions
Keys
Time duration
Beginning time/
Brightness grade
Light on time
Null
Color
Mix
Null
White
(beginning time)
Factory settings
Null
Blue
Network connection
The network function only applies when using two or more
lighting
LL-4800N
fixtures. Using standard RJ45 network cables, all of
lighting fixtures can
LL-4800N
be connected and synchronized to operate efficiently and conveniently.
Figure I
LL-4800N
LL-4800N
LL-4800N
LL-4800N
LL-4800N
A (Master)
D (Slave)
C (Slave)
B (Slave)
9
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
Case 1 -Step1) If “A” fixture is as a master and others are slaves, “OUT”
ethernet port of “A” fixture should be connected to “IN” ethernet
port of “B” fixture by the network cable. Then, “OUT” ethernet
port of “B” fixture should be connected to “IN” ethernet port of “C”
fixture.(Refer to figure l below.)
Step2
)
Lastly
,
press
“IN”
for
all
of
slaves
with
the
remote controller
and they will be ready to receive signals from the master.
Step3)
Now, you can adjust time, lighting mode, or other settings from
the master and all of slaves will be synchronized to operate as one.
16
15
1C 0 1
1A0 1
2A1 0
3A2 8
4A1 5
5A0 2
2C 2 8
3C 2 8
4C 3 0
5C 0 2
1 0 1
2 0 5
3 2 8
4 1 0
5 1 0
E (Slave)