C8000
Frame Controller
C8702
digital audio
modular
processing system
Page 5/23
Setting the mode switch for single power supply operation:
•
if only one power supply is installed (e.g. the C8911 frame has only one PS)
the mode switch
“B”
must be set to
ON
in order to turn power fail monitoring off.
Setting the mode switch for C8942 high density frames:
•
For the C8942 frames the mode switch
“C”
must be set to
ON
to turn
sync fail monitoring off
(this frame type has no central sync source) and
fan monitoring on
.
Setting the mode switch for C8912 dual power supply 19" 1RU frames:
•
For the C8912 frames the mode switches
“C”
and
"D"
must be set to
ON
to turn
fan monitoring on
.
Reset the C8702:
•
press the
INIT
button briefly at any time and the Frame Controller will reboot immediately.
Important Note!
Rebooting the Frame Controller has
no effect
on
audio processing
.
Initialize the C8702 to
factory default
settings:
•
Approx. 40 sec. after power is turned on or after pressing the
INIT
button briefly (reset function),
the
STATUS LED
lights yellow. Now you may press the
INIT
button and hold it firmly until the
STATUS LED
flashes three times. This is an acknowledgement that the C8702 has been
initialized to factory default settings (you may also hold down the
INIT
button at any time until the
STATUS LED
flashes three times).