C8000
Frame Controller
C8702
digital audio
modular
processing system
Page 21/23
Important Note!
The module for replacement
must
be of the
same type
and
must
have the
same CAN
address
. If a
different module type
is used with the
same CAN address
as the one removed,
you
must
reboot
the Frame Controller!
Under some circumstances the
browser session
with the web server of the
C8702
Frame Controller
will
expire.
In this case you must reload [F5] or close the browser and start it again in order to open a new session.
To change values of parameters more comfortably we use a little
slider
.
After clicking into such an input field, the slider may either be
moved
by the
mouse pointer
or the
arrow keys
of the keyboard or by the
mouse wheel
.
Error monitoring and
auto switch over
on error conditions
This function is implemented for the
C8402/03/04/05 SDI
modules. It allows the detection of an error
condition downstream in the signal path. Such an error condition may happen if a downstream
DSP module like the C8086+ has a problem or its input signal is gone. This function offers you the
possibility to switch over to an alternative bus for fail save operation. Such an alternative bus may be
the input of the DSP module for simply bypassing it (if the moduel fails) but it may also be an
alternative audio signal such as a pre-recorded announcement.
For details see C8402/03/04/05 manual.