background image

TRONIC amplifier, built-in 

Light Management  

TRONIC amplifier, built-in 

Art.-No.: 247 EB

Operationsmanual 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 
The load is not electrically isolated from the mains even when the device is switched off. 

Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent 
lamps or LED lamps. Device can be damaged. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

picture 1 

(1)  Power extension 
(2)  Load connection 
(3)  Dimmer connection 

3 Function 

Intended use 

Output extension of TRONIC dimmers, which work according to the phase section 
principle. 

Output extension of universal dimmers, which have detected an ohmic or capacitive basic 
load. 
Do not operate universal dimmers with an inductive load. 

Connection of filament lamps, HV halogen lamps and TRONIC transformers with halogen 
lamps. 

Suitable for mixed operation up to the specified output (see chapter 5.1. Technical data) 

Do not operate the corresponding dimmers without a load. 

Installation in false ceilings or surface mounting 

1/4 

82539913 
J:0082539913 

11.08.2010 