background image

Room thermostat (1-way NC contact) 230 V

Valve protection function (once a week opening and closing of valve)

5

Operation

Increasing or reducing the room temperature

Turn the control knob to the right or left.
In the middle position, the device regulates to approx. 20 °C setpoint temperature. The
room temperature reached depends on the installation location of the device and the am-
bient conditions. The lowest setpoint temperature is approx. 5 °C and the highest setpoint
temperature is approx. 30 °C

6

Information for electrically skilled persons

Selecting a suitable installation location

Recommended installation height: 1.50 m on interior walls

Do not mount the device near sources of interference, such as ovens, refrigerators,
draughts (e.g. next to the door) or direct sunlight. This affects the temperature measure-
ment of the internal temperature sensor.

Do not mount the device within shelf walls or behind curtains and similar covers

Do not use the device in multiple combinations with heat-generating devices such as dim-
mers

 DANGER!

Mortal danger of electric shock.

Disconnect the device. Cover up live parts.

Connecting and fitting the device

Figure 2: Connection example of the insert

2 / 4

82404803

05.05.2022

J0082404803

Отзывы: