Operating push-button actuator

o

Press the control surface of the app. The load is switched on for the length of actuation.

i

The maximum actuation length is 60 seconds.

Recalling scenes

o

Briefly press the control surface of the app.
Actuators switch to the saved scene.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

Installing the wall bracket

Figure 2: Hole spacing, wall bracket

To ensure good transmission quality, keep a sufficient distance from any possible sources of
interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or
transformers.

o

Fasten the wall bracket with countersunk head screws and push the Gateway into the wall
bracket.

3/8

82589503
J:0082589503

27.03.2014

eNet

Radio IP gateway

Содержание FM-GATE-IP

Страница 1: ...d customer 2 Device components Figure 1 Gateway 1 Status LED 2 Button Update Prog 3 USB connection for power supply 4 Ethernet connection 3 Function System information This device is a part of the eNe...

Страница 2: ...ion Supplementary functions can be activated via eNet server Operation locks i The parameter list is in the Internet in the documentation for this device Supplementary function with eNet server Readin...

Страница 3: ...for electrically skilled persons 5 1 Fitting and electrical connection Installing the wall bracket Figure 2 Hole spacing wall bracket To ensure good transmission quality keep a sufficient distance fr...

Страница 4: ...ED of the LAN connection flashes during data transmission The Status LED 1 flashes green the Gateway is obtaining the IP address of the WiFi router via DHCP The Status LED 1 turns green meaning the Ga...

Страница 5: ...han an update is taking place o Download the new app onto the tablet PC or smartphone o Start the update o When requested to do so by the app Press the Update Prog button on the Gateway After a few se...

Страница 6: ...able subnet mask Basic setting 255 255 255 0 Setting of the subnet mask Standard Gateway Freely settable IP address Basic setting 192 168 0 1 Setting of the Standard Gateway DHCP On Off Basic setting...

Страница 7: ...0 seconds Cause No LAN connection available Check the LAN connection Gateway does not obtain the IP address from the router or access point Cause Router or access point does not support DHCP After app...

Страница 8: ...for by law Please send the device with a description of the defect to our central customer service office ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 2...