Figure 3: Installing the power pack

o

Slacken the two screws (5) and remove housing lid (4) (figure 1).

o

If necessary break out cable entry (8) for flush-mounted cable routing (figure 3).

o

Fasten power pack with two screws (6).

o

Route cables into the housing and connect to the terminals (7) (see Connecting the power
pack).

i

The power pack has double terminals for looping the connecting cables through.

o

Put the housing lid on and fasten with the screws.

Connecting the power pack

The power pack can be connected in various ways.

o

Select the appropriate connection diagram depending on what installations are present.

Figure 4: Connecting the power pack

Each time the push-button (normally closed contact) is pressed, a switching operation of the
power pack is triggered (figure 4).

4/9

32529813
J0082529813

02.11.2016

Radio Management 

Radio performance unit

Содержание FLW2200WW

Страница 1: ...uries fire or property damage possible Please read and follow manual fully The radio communication takes place via a non exclusively available transmission path and is therefore not suitable for safet...

Страница 2: ...hout light control 4 Operation Normal operation In normal operation the power pack switches the load on for the set switch on time when a taught radio motion detector telegram is received Switching on...

Страница 3: ...vice changes over to normal operation Switch off for 2 hours o Operation with installation button press push button three times briefly Or o Operation with radio transmitter Press taught channel butto...

Страница 4: ...r pack has double terminals for looping the connecting cables through o Put the housing lid on and fasten with the screws Connecting the power pack The power pack can be connected in various ways o Se...

Страница 5: ...en the power pack is switched on again switch S1 triggers a switching operation while S2 does not Figure 6 Changeover switch Changeover switches that are present can be replaced by push button T a nor...

Страница 6: ...ual mode power pack without function figure 7 Figure 8 Connection in parallel with automatic staircase light switch impulse relay The lighting is switched on either by the automatic staircase light sw...

Страница 7: ...o screws 5 and remove housing lid 4 figure 1 o Turn rotary switch PROG 12 to ON to activate the programming mode figure 9 The red LED flashes o Trigger a teach telegram with the radio transmitter bein...

Страница 8: ...434 79 MHz Receiver category 2 Teachable radio transmitter max 30 6 2 Troubleshooting Load does not switch on LEDs are off Cause 1 device has no mains voltage supply Connect device to mains voltage o...

Страница 9: ...U Declaration of Conformity is available under the Internet address www jung de ce 6 4 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law ALB...

Отзывы: