Jung eNet FM GATE 1 ZSNA Скачать руководство пользователя страница 6

Disconnect the connection between the Radio Management transmitter and the eNet
actuator

Figure 6: Disconnecting

o

Press the 

Prog

 button (3) of the gateway for approx. 4 seconds.

The LED (2) of the gateway flashes slowly. The device is in programming mode for
approx. 1 minute.

o

Also switch all the eNet Bus actuators to be disconnected to programming mode (see
actuator instructions).

o

Press the channel button on the Radio Management transmitter for longer than one second
or the scene button for longer than three seconds.
The gateway detects that the actuator was previously connected and instigates the
disconnection operation.
The eNet actuator is disconnected. The actuator exits programming mode automatically.

Resetting the device to the factory setting

All the connections in the gateway between transmitters and actuators are disconnected.
Recommissioning must take place.

i

Before resetting to the factory setting, disconnect connected Radio Management actuators
(see Disconnecting the connection to the Radio Management actuator). This ensures that
setting up new connections does not cause unintentional switching operations.

o

Press the 

Prog

 button for at least 20 seconds.

The status LED flashes after 4 seconds. After 20 seconds the status LED flashes faster.

o

Release the 

Prog

 button and press it once again within 10 seconds.

All the connections are disconnected. The status LED flashes more slowly for approx. 5
seconds.

5 Appendix

The icon confirms the conformity of the product to the relevant guidelines.

5.1 Technical data

Rated voltage

AC 230 V ~

Mains frequency

50 / 60 Hz

Rated load current

16 A (I

L

)

Power consumption

max. 1 W

Degree of protection

IP 20

6/8

82582113
J:0082582113

13.03.2014

eNet

Radio converter in SCHUKO housing

Содержание eNet FM GATE 1 ZSNA

Страница 1: ...re an integral part of the product and must remain with the end customer 2 Device components Figure 1 Gateway 1 SCHUKO socket with increased contact protection 2 Red status LED covered 3 Button Prog 3...

Страница 2: ...ion This device serves an interface between the Radio Management 433 MHz and eNet 868 MHz systems It allows operation of the actuators in the other system figure 2 i Status feedback is only provided b...

Страница 3: ...Press the Prog button 3 of the gateway for approx 4 seconds The status LED 2 of the gateway flashes slowly The device is in programming mode for approx 1 minute o Switch the eNet transmitter to progr...

Страница 4: ...r the scene button for longer than three seconds The connection to the actuator is disconnected The LED of the actuator flashes quickly o Exit the programming mode of the Radio Management actuators se...

Страница 5: ...tors which are to react to the channel or scene button to programming mode as well see actuator instructions i Up to 10 eNet actuators can be connected at the same time o Press the channel button on t...

Страница 6: ...ctions in the gateway between transmitters and actuators are disconnected Recommissioning must take place i Before resetting to the factory setting disconnect connected Radio Management actuators see...

Страница 7: ...nction Manual commissioning On Off Basic setting On With this device the parameter has no function Sum status transmission repetitions On Off Transmit 2x 11x Off Transmit 4x without connection Basic s...

Страница 8: ...e 1 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 2 04 kundencenter jung de www jung de Service Center Kupferstr 17 19 44532 L nen Germany 8 8 82582113 J 0082582113 13 03 2014 eNet...

Отзывы: