background image

Universal automatic switch 1.1 m

Recommendation: Use air-tight appliance boxes.

Product characteristics

Automatic switching of light, depending on heat motion and ambient brightness

2 PIR sensors

Detection area 180°

Integrated brightness sensor

Adjustable switch-off brightness

Adjuster for manual adjustment of sensitivity

Output functions: Switching, value transmitter, light scene extension, staircase function,
switching with forced position, operating mode setting for room temperature controller

Extension of the detection field by way of operating several devices as main unit or exten-
sion unit

Status LED

Manual switching on the device

Detection field can be dimmed by 50%

Manual operation with IR remote control possible (accessories)

5 function blocks for motion detection each with 2 outputs

Function blocks switchable, e.g. for day/night operation

Brightness sensor function with 3 limiting values

Alarm when unplugging from the bus coupler

Temperature measurement

Motion detection function

The detection of movements is done through the "passive infrared" principle ("PIR"). The device
generally reacts to heat radiation changes within its detection area. This is achieved with the
help of the so-called PIR sensors, which are highly sensitive in the infrared range. The geome-
try of the detection field is ensured by a lens system that lets infrared light pass through and
concentrates incident radiation on the sensors. So-called "detection radiation" are formed
through the lens system and cause a clear signal jump to be detected when they enter.

Note: The term "detection radiation" refers to the imaginary line that begins in the sensor, goes
through the lens system and continues in a straight line outside of the device. The device itself
does not emit any radiation.

Figure 

3

: Thermal image of a person and their reflection on the ground

The detection of heat sources through a motion detector is influenced by the following criteria:

Geometry of the detection field:
A motion detector that faces downwards at an angle is different from one that looks

 

straight ahead into infinity (Figure 

4

).

Distance between heat source and motion detector: the further away the heat source is

 

from the sensor, the weaker the evaluable signal on the sensor (Figure 

4

).

Size of the heat source, e. g. adult or child (Figure 

5

)

Temperature of the heat source: surfaces at 98.6 °F (37 °C) radiate more intensely than at

 

50 °F (10 °C) (Figure 

5

). 

3 / 13

32597025

05.09.2018

J0082597025

Содержание A3181-1-01

Страница 1: ...Article numbers A3181 1 01 A3181 1AL 01 A3181 1ANM 01 A3181 1CH 01 A3181 1MO 01 A3181 1SW 01 A3181 1WW 01 AL3181 1 01 AL3181 1AN 01 AL3181 1D 01 ES3181 1 01 LC3181 1 01 LS3181 1 01 LS3181 1LG 01 LS318...

Страница 2: ...of this device depends upon the software Detailed information on loadable soft ware and attainable functionality as well as the software itself can be obtained from the manu facturer s product databa...

Страница 3: ...changes within its detection area This is achieved with the help of the so called PIR sensors which are highly sensitive in the infrared range The geome try of the detection field is ensured by a len...

Страница 4: ...nse be havior Sensor sensitivity the sensor sensitivity can be adjusted according to application and en vironment Low heat contrasts outdoors may require a high sensitivity that is far to high for ind...

Страница 5: ...about 64 4 F 18 C average humidity used in a hallway with walking people Higher ranges are to be expected for lower ambient temperature note season specific clothing more intense movement of persons r...

Страница 6: ...arameter dependent or IR reception RD Red Programming mode is active 6 IR remote control Function buttons IR remote control Button Function Detection of a motion is sent for function block 1 The autom...

Страница 7: ...e g light Press button Switch off e g light Press button Set automatic mode Press button Manually change settings with IR remote control If enabled individual settings for function block 1 can be chan...

Страница 8: ...tection field The detection field can be limited as required Figure 9 Switch off the left or right PIR sensor with parameter setting Detection angle approx 100 or Mounting the cover Detection angle ap...

Страница 9: ...ng To achieve optimum range choose an installation location that is transversal to the direc tion of motion Avoid interference sources in the detection area Interference sources e g heaters venti lati...

Страница 10: ...ensity and sensitivity decrease 4 High sensitivity 1 Low sensitivity The specifications on the extent of the detection area are general guide values Discrep ancies can occur depending on the installat...

Страница 11: ...re 16 Mount the cover for the left or right side of the device 3 Figure 17 Range A Mount the cover from the front on the left or right side of the device Figure 17 Mount device Prerequisite Bus couple...

Страница 12: ...active accord ing to their programmed sensitivity Pace off the detection field paying attention to reliable detection and interference sources Any motions detected are displayed by the blue LED Limit...

Страница 13: ...Construction of control Independently Mounted Control for Flush Mounting Pollution Degree PD 2 Impulse Voltage 330 V 8 2 Accessories Bus coupling unit 3 Art No 2073U 01 IR remote control Art No KNXPMF...

Отзывы: