background image

Adjusting the slats

o

Press top or bottom of cover for shorter than one second.
The slat position changes in the desired direction for as long as the button is pressed.

Operation with radio transmitter

A radio transmitter has to be taught in order to be able to operate the venetian blind via radio.

i

Observe the instructions for the radio transmitter.

The slats are adjusted or the Venetian blind is moved depending on how long a radio
transmitter is actuated.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.

Fitting the device

The Venetian blind control is mounted and connected properly (see instructions for the relevant
Venetian blind control).

o

In the case of covers with sensor connections, install the sensor cable, adjust the
brightness threshold and fasten the sun sensor to a window (see following chapter):

o

Mount the radio cover with the frame onto the Venetian blind control (figure 1).

o

Switch on mains voltage.

Installing the sensor cable
for covers with sensor connections

i

The sensor cable carries safety extra-low voltage (SELV). Observe fitting instructions
according to VDE 0100.

The sensor cable can be installed in three different ways. In-wall routing (figure 3), surface-
mounted routing (figure 4), and with appropriate covers plugging the sensor cable into the
cover.

i

The sensor cable must not be too long, because otherwise interference from other loads
and cables may occur. This may result in malfunctions. Therefore use only shielded cables,
and connect the shielding to earth. The total length must not exceed 20 m; avoid proximity
to other electrical facilities.

3/7

32524333
J0082524333

13.09.2016

Blinds Management 

Centre plate with radio receiver, Centre plate with radio receiver and
sensor connection

Содержание 5232F Series

Страница 1: ...electric shock Device is not suitable for disconnection from supply voltage The radio communication takes place via a non exclusively available transmission path and is therefore not suitable for safe...

Страница 2: ...les automatic shading when it is very bright outside The brightness threshold that controls the sun protection can be adjusted on the cover If the measured brightness exceeds the predefined brightness...

Страница 3: ...netian blind control o In the case of covers with sensor connections install the sensor cable adjust the brightness threshold and fasten the sun sensor to a window see following chapter o Mount the ra...

Страница 4: ...connection o Connect the cable see Connecting sensors to terminal block Routing the sensor cable with surface mounting Figure 4 Surface mounted routing of the sensor cable o For surface mounted routi...

Страница 5: ...ensor to the cover if a corresponding socket is present This is not the case for all covers with sensor evaluation o Insert plug of sun sensor into the socket of the cover Fasten sun sensor to the win...

Страница 6: ...d light scenes of the radio transmitter individually The distance between the receiver and the radio transmitter is from 0 5 m to 5 m The load is switched off o Press cover over entire surface for app...

Страница 7: ...5 MHz 434 79 MHz Receiver category 2 Teachable radio transmitter max 30 6 2 Troubleshooting The sun protection is not performed properly instead the Venetian blind moves into the direction of the lowe...

Отзывы: