1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the devise or
load. In so doing, take all the circuit breakers into account, which support dangerous
voltages to the device and or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage.

The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: Device components

(1) Venetian blind control
(2) Frame
(3) Radio cover

3 Function

System information

By statute, the transmitting power, the reception characteristics and the antenna cannot be
changed.
The range of a radio system from the transmitter to the receiver depends on various
circumstances.
The range of the system can be optimised by selecting the optimal installation location, taking
into account the structural circumstances.

1/7

32524333
J0082524333

13.09.2016

Содержание 5232F Series

Страница 1: ...electric shock Device is not suitable for disconnection from supply voltage The radio communication takes place via a non exclusively available transmission path and is therefore not suitable for safe...

Страница 2: ...les automatic shading when it is very bright outside The brightness threshold that controls the sun protection can be adjusted on the cover If the measured brightness exceeds the predefined brightness...

Страница 3: ...netian blind control o In the case of covers with sensor connections install the sensor cable adjust the brightness threshold and fasten the sun sensor to a window see following chapter o Mount the ra...

Страница 4: ...connection o Connect the cable see Connecting sensors to terminal block Routing the sensor cable with surface mounting Figure 4 Surface mounted routing of the sensor cable o For surface mounted routi...

Страница 5: ...ensor to the cover if a corresponding socket is present This is not the case for all covers with sensor evaluation o Insert plug of sun sensor into the socket of the cover Fasten sun sensor to the win...

Страница 6: ...d light scenes of the radio transmitter individually The distance between the receiver and the radio transmitter is from 0 5 m to 5 m The load is switched off o Press cover over entire surface for app...

Страница 7: ...5 MHz 434 79 MHz Receiver category 2 Teachable radio transmitter max 30 6 2 Troubleshooting The sun protection is not performed properly instead the Venetian blind moves into the direction of the lowe...

Отзывы: