Jung 1704ESE Скачать руководство пользователя страница 1

Operating instructions

Electronic switch insert 1-channel
Art. no. 1704ESE

25.08.2022

82400533 J0082400533

ALBRECHT JUNG GMBH & CO. KG
Volmestraße 1
58579 Schalksmühle
GERMANY

Telefon: +49 2355 806-0
Telefax: +49 2355 806-204
[email protected]
www.jung.de

Содержание 1704ESE

Страница 1: ...ectronic switch insert 1 channel Art no 1704ESE 25 08 2022 82400533 J0082400533 ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundence...

Страница 2: ...eristics 3 4 Operation 4 5 Information for electrically skilled persons 4 5 1 Mounting and electrical connection 4 5 2 Commissioning 7 6 Technical data 8 7 Troubleshooting 9 8 Accessories 10 9 Warrant...

Страница 3: ...mode and load type do not match Set correct operating mode when connecting or exchanging the load This manual is an integral part of the product and must remain with the end cus tomer 2 Intended use O...

Страница 4: ...ontrol principle Automatic or manual setting of the suitable operating mode for the load Indication of the set operating mode by means of LED Brief flickering upon load detection possible No operation...

Страница 5: ...connected load on LED lamps is dependent on the type of lamp and in stallation conditions The connected load of the specified values could vary We cannot assume any guarantee for proper function Opera...

Страница 6: ...stallation height 1 50 m Image 3 Connection diagram in combination with a room thermostat cover and KNX RF push button 6 Switching contact for switching to cooling mode 7 Electrothermal valve drive If...

Страница 7: ...nt lamps HV halogen lamps dimmable HV LED or compact fluor escent lamps dimmable electronic or inductive transformers for halogen or LED lamps LED trailing edge phase control The connection of inducti...

Страница 8: ...cal data Rated voltage AC 230 V Mains frequency 50 60 Hz Standby load depending on the cover approx 0 1 0 5 W Power loss approx 4 W Ambient temperature 5 45 C Light loads Connected load at 25 C see fi...

Страница 9: ...on unlimited 3 wire rotary extension 10 Total line length Extension max 100 m Power cable max 100 m Loads for room temperature control Thermal valve drive NC order no TSA230NCWW Number 1 10 7 Troubles...

Страница 10: ...D leading edge phase control setting reduce connected load as well if necessary Exchange lamps for another type Cause 3 Short circuit protection has tripped Disconnect device from mains by switching o...

Страница 11: ...JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de Electronic switch insert 1 channel 11 11 82400533 25 08 2022 J00...

Отзывы: