Jung 1240 STE Скачать руководство пользователя страница 7

 

Light Management

 

Pushbutton control unit 
Ref.-no.: 1240 STE  
R3 

 

6. Technical Data   

Nominal voltage :    

 

 

AC 230 V ~, 50 / 60 Hz 

Power rating: 

incandescent lamps :    

 

700 W 

electronic ballasts :  

 

 

type-dependent 

Number of Extensions: 

"2-wire" extension insert, 
mechanical push-button :  

 

unlimited 

"3-wire" extension insert :  

 

10 

Different types of extension units can be combined. 
Illuminated mechanical pushbuttons must have a separate N terminal. 
Emitted interference :  

 

 

acc. to EN 55015 

Control voltage :  

 

 

 

0,5 .. 10 V 

Control current :  

 

 

 

max. 50 mA 

Switching contact : 

relay contact at mains 
potential 

Total length of cable to 
extension units :  

 

 

 

max. 100 m 

 

7. Guarantee 

Our products are under guarantee within the scope of the statutory 
provisions. 

Please return the unit postage paid to our central service 
department giving a brief description of the fault: 

ALBRECHT JUNG GMBH & CO. KG 
Service-Center 
Kupferstr. 17-19 
D-44532 Lünen 
Service-Line: 

+(49) 23 55 . 80 65 51 

Telefax: 

+(49) 23 55 . 80 61 65 

E-Mail: [email protected] 

General equipment 

Service-Line: 

+(49) 23 55 . 80 65 55 

Telefax: 

+(49) 23 55 . 80 62 55 

E-Mail: [email protected] 

KNX equipment 

Service-Line: 

+(49) 23 55 . 80 65 56 

Telefax: 

+(49) 23 55 . 80 62 55 

E-Mail: [email protected] 
 

The 

-Sign is a free trade sign addressed exclusively to the 

authorities and does not include any warranty of any properties. 

 

 

Содержание 1240 STE

Страница 1: ...ic ballasts or TRONIC transformers with 1 10V interface Switching and dimming commands are given by actuating the attachments for the pushbutton control units extension units or radio control transmit...

Страница 2: ...itself For storing press the center of the button not multifunction pushbutton with radio control receiver and multifunction pushbutton Universal for at least 20 seconds when off The lights are at fi...

Страница 3: ...ation the max load connected must be reduced 10 for every 5 C above the ambient temperature of 25 C 15 for installations in wooden gypsum plasterboard or hollow walls 20 for installations in multi dev...

Страница 4: ...1240 STE R3 1 pushbutton control unit 5 load 6 switched phase to other loads 7 1 10 V control lines to other loads 8 2 wire extension unit art no 1220 NE 9 3 wire extension insert art no 1223 NE 10 m...

Страница 5: ...Functions available only if an automatic switch or a presence detector attachment is used also on the main unit Extension unit 2 wire with short stroke key Same functions as with the pushbutton contr...

Страница 6: ...rt is connected as shown in fig C The number of electronic ballasts or TRONIC transformers that can be dimmed with a single pushbutton control unit depends on the control current of the individual ele...

Страница 7: ...ns potential Total length of cable to extension units max 100 m 7 Guarantee Our products are under guarantee within the scope of the statutory provisions Please return the unit postage paid to our cen...

Отзывы: