Technical data

KNX
KNX medium

TP256

Safety

X-mode

Commissioning mode

S-mode

Rated voltage

DC 21 ... 32 V SELV

Current consumption KNX
without push-button extension or external switching con-
tacts

4.9 ... 8.2 mA

with push-button extension

6.6 ... 9.4 mA

with external switching contacts

7.7 ... 11.0 mA

Connection mode KNX

Standard device connection terminal

Connecting cable KNX

EIB-Y (St)Y 2x2x0.8

Protection class

III

Push-button extension connection (see accessories)
Number

1

Cable type

J-Y(St)Y 2×2×0.8

Cable length

max. 30 m

External switching contact connection
Number

max. 20

Cable type

J-Y(St)Y 2×2×0.8

Cable length

max. 30 m

Ambient conditions
Ambient temperature

-5 ... +45 °C

Storage/transport temperature

-25 ... +70 °C

8

Accessories

KNX push-button extension 1-gang

Art. no. ..10911TE

KNX push-button extension 2-gang

Art. no. ..10921TE

Rocker for KNX push-button 1-gang

Art. no. ..101..

Rocker for KNX push-button 2-gang

Art. no. ..102..

11 / 12

82402103

19.02.2020

J0082402103

Содержание 10711ST Series

Страница 1: ...t no 10721ST KNX push button extension 1 gang Art no 10911TE KNX push button extension 2 gang Art no 10921TE Operating instructions 1 Safety instructions Electrical devices may only be mounted and con...

Страница 2: ...on standard KNX push button extension 2 Device components Figure 1 Device components 1 channel Figure 2 Device components 2 channel 1 Design frame accessories 2 Status LED 3 Operating rockers accessor...

Страница 3: ...nning installation and commissioning of the device are carried out with the aid of the ETS version 5 7 3 and above Intended use Operation of loads e g light on off dimming Venetian blinds up down brig...

Страница 4: ...tion Button function Two buttons above one another per form the same function Each button can perform an indi vidual function Universal For the rocker functions Dimming Venetian blind and 2 channel op...

Страница 5: ...unting with 230 V socket outlets under a common cover there is a danger of electrical shocks in the event of a fault Use only the enclosed plastic screws for fastening to the supporting frame Mount su...

Страница 6: ...ol our coding black SW red RT white WS yellow GE The connection terminal blocks are included with the Do not exceed the cable length max 30 m One Push button universal can be connected per Do not conn...

Страница 7: ...KNX push button universal KNX push button standard KNX push button extension Do not connect any external voltage Figure 5 Connecting installation push button 7 12 82402103 19 02 2020 J0082402103...

Страница 8: ...physical address into the device The status LEDs return to their previous state off on or flashing Physical address is programmed Write the physical address on the device label Load the application p...

Страница 9: ...a master reset The status LEDs flash rapidly approx 4 Hz The device restarts The status LEDs flash slowly approx 0 75 Hz Only release the the top left and bottom right buttons when the LEDs flash Res...

Страница 10: ...ng the operating rockers Figure 7 The operating rockers can be dismantled using a dismantling wedge or a screwdriver Figure 8 The recesses are intended for a blade width of up to 4 mm Figure 7 Dismant...

Страница 11: ...tion terminal Connecting cable KNX EIB Y St Y 2x2x0 8 Protection class III Push button extension connection see accessories Number 1 Cable type J Y St Y 2 2 0 8 Cable length max 30 m External switchin...

Страница 12: ...rranty The warranty is provided in accordance with statutory requirements via the specialist trade ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 23...

Отзывы: