background image

Troubleshooting/FAQs

Q. What should I do if the Jump-N-Carry

®

will not hold a charge?

A. Load test the battery. Charge battery 24 hours before load testing. Connect a load

tester (available at your local auto parts store) to the Jump-N-Carry

®

clamps to

check battery amperage. Depending on the model of load tester, your load testing
procedure may vary. A generic load test would bring the voltage down to 9.0 volts
and result in an amp reading of 70 amps for 6 seconds. Repeat this load test every
10 minutes for a total of three tests. If the amperage has dropped below 50 amps
on the last test, suspect a bad or weak battery.

Q. What is the ideal use for the Jump-N-Carry

®

?

A. The Jump-N-Carry

®

performs strongly when a vehicle’s battery needs an extra

boost because a light or radio was left on, or when a vehicle has been sitting for a
long period of time. The Jump-N-Carry

®

will start vehicles without any other

batteries present, but the primary use is for an extra boost.

Q. Will the Jump-N-Carry

®

start every vehicle?

A. No. In addition to a dead battery, a car may have other mechanical problems that

would prevent the Jump-N-Carry

®

from starting the vehicle.

Battery Replacement and Disposal

The Jump-N-Carry

®

battery may be removed by unscrewing the perimeter screws on

the back cover. Disconnect the wires from the battery terminals. Note the position of the
battery and wire locations.

• Two wire connections go to each terminal.

• The small wires are color coded – red for positive, black for negative.

• The large cable is identified by the color of the clamp attached to the cable – red

for positive, black for negative.

Caution: It is possible for the cables to become crossed inside the case when the
battery is removed. The cables always travel straight to the battery terminals and
should never cross each other.

• All red wires (red clamp) attach to the positive side of the battery. All black wires

(black clamp) attach to the negative side of the battery.

• To connect a new battery, slide the battery fully into the case. Note the color of the

wires and match the color to the battery terminals.

• Replace the perimeter screws on the back cover.

• Charge the for 24 hours upon installation of a new battery.

The authorized replacement battery for the Jump-N-Carry

®

JNCAIR is the Clore

PROFORMER Battery Model No. JNC105. JNC105 is a kit that includes the battery and
all necessary hardware.

Pb

This unit contains a sealed non-spillable lead-acid battery.
This battery must be recycled.

Consult your state or local

government concerning regulations for proper disposal.

 

Содержание JNC Air

Страница 1: ...ber to recharge the unit for 24 hours at least every 3 months during the winter and monthly during the summer Charge the unit for 24 hours through the built in charger upon opening the box charge after every use and charge before extended storage Pb CONTAINS SEALED LEAD ACID BATTERY BATTERY MUST BE RECYCLED Failure to follow instructions may cause damage or explosion always shield eyes Read entire...

Страница 2: ...low these instructions for safe use Always follow the specific instructions in this manual and on the Jump N Carry each time you jump start using the Jump N Carry All lead acid batteries car truck and boat produce hydrogen gas which may violently explode in the presence of fire or sparks Do not smoke use matches or a cigarette lighter while near batteries Do not handle the battery while wearing vi...

Страница 3: ... When jump starting do not use the unit for more than 6 seconds without a 3 minute rest period between use See the Warranty for important details To ensure trouble free use please remember to recharge the unit for 24 hours at least once every 3 months during the winter and monthly during the summer see Recharging Jump N Carry section Air Compressor Instructions 1 Remove valve stem cap and connect ...

Страница 4: ...auge Press and hold the red test button to display the battery status on the gauge The Green shaded area indicates the unit is capable of jump starting The Yellow shaded area indicates the unit needs to be recharged The Red shaded area indicates the unit must be recharged before use You can also get a quick check of the vehicle s charging system by depressing the red test button while connected to...

Страница 5: ...charging is complete It is recommended that the Jump N Carry be recharged after every use SUGGESTED AC RECHARGE TIMES After a single jump start 1 hour After using the air compressor 12 hours or overnight After using as portable power 24 36 hours Recharging Using 12 Volt Power Jump N Carry may also be recharged by using the included Male Male 12V Extension Cord Part No ESA1 Plug one end into the 12...

Страница 6: ... and Disposal The Jump N Carry battery may be removed by unscrewing the perimeter screws on the back cover Disconnect the wires from the battery terminals Note the position of the battery and wire locations Two wire connections go to each terminal The small wires are color coded red for positive black for negative The large cable is identified by the color of the clamp attached to the cable red fo...

Страница 7: ...sult in overcharging the Jump N Carry battery and may void the product warranty Q What accessories can be used in the optional 12 volt outlet A Any accessory up to 12 amps can be powered by the Jump N Carry This unit is equipped with an automatic reset circuit breaker should the current exceed 12 amps At the same time this limits any recharge current through the 12 volt outlet to 12 amps One can p...

Страница 8: ...set forth above In no event shall Clore Automotive be liable for consequential or incidental damages Some states do not allow limitations on the length of the implied warranty or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary fr...

Отзывы: