Differential
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarm
➔
Differential
-99999 to 0 to +99999
(1) = Low limit
(2) = High limit
(3) = Differential
Text Low alarm
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarm
➔
Text
Low alarm
Standard text,
Text 1 — 18,
No text
v
v
Configuration
➔
Texts,
Text High alarm
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarms
➔
Text
High alarm
Standard text,
Text 1 — 18,
No text
Alarm delay
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarms
➔
Alarm delay
0 — 32767s
Alarm delay is activated at
a value > 0.
When activated, an alarm
will only be generated
when it has been present
for at least as long as it
takes for the set time to
elapse.