3 Operation and visualization
38
3.2.6 Evaluation of the stored measurement data
History
The softkey function changes during evaluation. In addition, the current zoom
factor and cursor position (date and time) will be shown.
Scroll operation
Using these softkeys, the measurement data display can be scrolled (shifted)
on the screen within the measurement data stored in the internal memory.
H
Measurement acquisition remains active during history
representation.
Cursor (violet)
Current zoom
(magnification)
Scroll forwards fast
(one screen)
Scroll forwards slowly (one pixel line)
History
activated
Switch to
softkey functions
Zoom/Search
Date and time of measurements at
the cursor position
Scroll backwards slowly (one pixel line)
Scroll backwards fast (one screen)
Measurement at the
cursor position