13
4 Electrical connection
4
Electrical connection
NOTE!
When using the device with UL approval, the user must make sure that the accessory he uses is also
approved for a UL application (e. g. cable with UL approval AVLV2/8 and/or cable with UL approval
CYJV/7 or CYJV/8 or PVVA/7 or PVVA2/8, in each case approved for ambient temperatures > 90 °C).
Connection
Terminal assignment
M12 x 1 round plug (A-coded, non-rotating)
Switch operation
Voltage supply
a
DC 9.6 to 32 V
1 BN (brown)
b
3 BU (blue)
L+
L-
Switching output 1
4 BK (black)
C/Q = OUT1
Switching output 2
2 WH (white)
I/Q = OUT2
IO-Link operation
Voltage supply
a
DC 18 to 32 V
1 BN (brown)
3 BU (blue)
L+
L-
IO-Link
4 BK (black)
C/Q = IO-Link
Switching output 2
2 WH (white)
I/Q = OUT2
Potential equalization
Functional bonding conductor FB
c
a
The auxiliary energy of the pressure sensor must meet SELV requirements. Furthermore, the device must be
equipped with an electrical circuit that meets the requirements of EN 61010-1 with regard to "Limited-energy cir-
cuits".
b
The colour coding is
only
valid for A-coded standard cables!
c
The pressure sensor must be connected to the plant's potential equalization system via the process connection.
BU
BK
WH
BN
L–
C/Q (IO-Link/OUT1)
I/Q (OUT2)
L+
1
3
4
2
Содержание dTRANS p35
Страница 2: ......
Страница 3: ...40205800T97Z000K000 DE 00656422 2022 10 21 JUMO dTRANS p35 Drucksensor mit IO Link Kurzanleitung...
Страница 17: ......
Страница 19: ...40205800T97Z001K000 EN 00656422 2022 10 21 JUMO dTRANS p35 Pressure Sensor with IO Link Brief Instructions...
Страница 33: ......
Страница 35: ...40205800T97Z002K000 FR 00656422 2022 10 21 JUMO dTRANS p35 Capteurs de pression avec IO Link Notice succinte...
Страница 49: ......
Страница 51: ......
Страница 52: ......