Instruction manual
73 11/2019
GB
Continuous drainage
(as shown in Fig 8)
Note: Only applicable to cooling and dehumidifying mode.
1.
Unscrew the drainage cover, and unplug the drainage plug.
2.
Set the drainage pipe (not include) into the water outlet.
3.
Connect the drainage pipe to the bucket.
The size of drainage pipe:
Internal diameter 18mm
Fig.8
CLEANING AND MAINTENANCE
Note: in order to avoid electric shocks, please power-off the machine
and pull out plug before maintenances or repairs.
Cleaning:
1.
Please pull out plug before cleaning.
2.
Use soft semi-dry cloth to clean the machine. Don’t use chemical
agents, such as benzene, alcohol, gasoline and so on, otherwise
the machine surface will be damaged, or even the machine itself.
3.
Don’t spatter water into the machine.
Filter screen
(as shown in Fig.9):
1.
Wash the filter screen once every two weeks. If it is blocked by
dust, efficiency of the air conditioning will be reduced.
2.
The upper filter screen frame: Unscrew the screws fixing the filter
screen and the rear housing to remove the filter screen, then clasp
the wedging block of the EVA filter screen frame with hands. Force
down from the outside to remove the filter screen frame.
3.
Put the filter screen into the warm water (about 40
℃
/104
℉
)
Содержание JHS-A005
Страница 1: ...Bedienungsanleitung 1 11 2019 D Lokales Klimager t JHS A005 Best Nr JHS A019 05KR2 A...
Страница 22: ...Mode d emploi 22 11 2019 F Climatiseur Local JHS A005 Best Nr JHS A019 05KR2 A...
Страница 42: ...Istruzioni per l uso 42 11 2019 I Condizionatore D aria Locale JHS A005 Best Nr JHS A019 05KR2 A...
Страница 62: ...Instruction manual 62 11 2019 GB Local Air Conditioner Best Nr JHS A019 05KR2 A...