THE IMPLEMENTATION

REG – 03TFT

 controller is a modern microprocessor device controlling the work of 

the pellet's burner. Implementation of advanced driver's algorithm and the flame sensor 

ensures   the   simplicity   of   maintenance   and   the   full   automatization   of   the   burning 

process. The usage of a graphic display with touch screen assures an easy and clear 

interaction between the use and the device. The driver is adapted also to working with 

the central heatings pump and warm usage water pump (optional). Thanks to these 

functions,   the   device   can   be   used   in   expanded   installations   of   the   central   heating 

without using additional steering devices. The regulator is also equipped with an output 

of room thermostat which enables the change of the furnace's working parameter after 

reaching a particular temperature in the room. To controller added timer functions – now 

user can set heating time. 

THE PRICIPLE OF WORKING

The device's work is based on providing fuel via steering the feeder appropriately 

and the work of a fan which steers the burning process. After reaching a particular 

temperature   of   the   heating   water,   the   driver   goes   into   the   mode   of   sustaining   the 

temperature   or   switches   the   burner   completely   off.   The   ignition   of   fuel   starts 

automatically   with   the   help   of   igniter   which   is   connected   to   this   driver.   The   driver 

enables the control of the furnace's work thanks to the room thermostat. It is possible 

to steer the heating in relation to the actual temperature in the room. The regulator is 

also   equipped   with   the   self-control   systems   (detecting   the   malfunction   of   the 

temperature's sensors) and mechanisms monitoring the furnace's work preventing from 

going beyond the range of safety for the installation of the central heating (STB). 

- 7 -

Содержание REG-03TFT

Страница 1: ...PROCESOR CONTROLLER OF THE PELLET S BURNER REG 03 TFT v1 0 INSTRUCTION OF INSTALLING AND THE MAINTENANCE 1 FAN CO CH PUMP STB STB IN BUILD C ROOM THERMOSTAT ALARMS FAN SPEED REGULATOR CLOCK TIMER IGNI...

Страница 2: ...JUMAR REG 03TFT 2...

Страница 3: ...AM 8 THE DRIVER S HANDLING 12 OPERATION CONTROLLER 14 ALARMS 16 WORKING MODES 18 MENU STRUCTURE 20 CENTRAL HEATING TEMPERATURE SETTINGS 21 WARM USAGE WATER TEMPERATURE SETTINGS optional 21 SETTINGS TA...

Страница 4: ...to the maintenance and the safe using of the device Before installing please read the instruction carefully and get to know the functioning of the driver Any questions occur contact with the JUMAR com...

Страница 5: ...others devices of high power without appropriate net filters Avoid putting signal wires in a direct contiguity and in parallel to energetic and powering wires Avoid closeness of remotely controlled de...

Страница 6: ...30V 2A 0 8A CH Pump relay 230V 2A 0 8A HUW Pump relay triac 230V 2A 0 8A Cleaning system relay 230V 2A 0 8A Protection Temperature build in STB 80 C 400 C Electric external Fuse 4A Inputs Room thermos...

Страница 7: ...ter after reaching a particular temperature in the room To controller added timer functions now user can set heating time THE PRICIPLE OF WORKING The device s work is based on providing fuel via steer...

Страница 8: ...and controlling elements to the controller Before connecting the regulator to network it is necessary to check all the connections carefully One has to take particular note of not placing 230V power...

Страница 9: ...ut 13 14 L N output output Feeder connector 15 16 L N output output Internal feeder connector Cleaning system connector Warm usage water pump connector 17 18 S1 GND input input Warm Usage Water sensor...

Страница 10: ...t Igniter connector 8 L output Air fan connector 9 L output Internal feeder connector 10 L output Cleaning system connector 11 x 12 N output Igniter connector 13 N output Air fan connector 14 N output...

Страница 11: ...CH CH Sensor Central heating water sensor CH 3 FEED Burner Sensor The sensor protects the burner against excessive temperature growth Bimetal sensor has to selected according to the burner 4 FIRE Fire...

Страница 12: ...he driver on on the LCD screen appears the programme s logo defining the type of the driver and the manufacturer s logo After a few seconds controller show measurement panel The following figure shows...

Страница 13: ...ner on the first start From that moment the warranty of the control device is counted If some problems with the device or configuration will be appear please contact with service Manufacturer s data c...

Страница 14: ...JUMAR REG 03TFT OPERATION CONTROLLER The main screen is divided into panels HEATING PANEL HUW PANEL BURNER PANEL The figure below shows how to switch between panels 14...

Страница 15: ...fferent colours symbolizing the work of the element e g Icon Description Function disable Function enable device is working Function enable device is not working 15 IGNITER FEEDER INTERNAL FEEDER AIR...

Страница 16: ...t with a new one The figure below visualized an exemplary screen informing about missing sensor or sensor damage The alarm will be also activated if the temperature exceeds safe value 90 C Exceeding t...

Страница 17: ...e temperature will exceed above pre set value the controller will launch the burner protection procedures and display a message The burner s operation is blocked during alarm After decreasing the temp...

Страница 18: ...howing the actual power of the burner PAUSE Sustaining the set temperature if the burner s working mode is in the mode of continuous work BURNING OFF Putting off the burner Active in the STOP mode or...

Страница 19: ...n this mode the status of the flame is constantly monitored The decline of the flame activates functions linked to the ignition of the pellet if the particular burner s function requires it The driver...

Страница 20: ...JUMAR REG 03TFT MENU STRUCTURE The controller menu is divided into eight groups HEATING HUW BURNER DEVICE CLOCK TIMER LOGS SERVICE The following figures show how to navigate between menus 20...

Страница 21: ...ecreasing the temperature below the set value Heating water temperature CH boiler hysteresis activates the burner function If there is no flame in the burner it will be ignited again In the picture be...

Страница 22: ...0 C BURNER SETTINGS PARAMETER NO PARAMETER NAME UNIT SETTING RANGE DEFAULT VALUE 1 MAX BURNER POWER kW 10 500kW 35kW 2 MIN BURNER POWER kW 2 90kW 3kW 3 WORKING MODE normal stop go normal 4 FEEDER FILL...

Страница 23: ...UEL 4 STB ALARM 5 BURNER ALARM 6 SENSOR ALARM 7 AVERAGE CONSUMPTION 8 TOTAL CONSUMPTION SERVICE SETTINGS PARAMETER NO PARAMETER NAME UNIT SETTING RANGE DEFAULT VALUE 1 SERVICE CODE CAUTION The manufac...

Страница 24: ...contact The pump is also automatically switched on if one of the emergency status appears e g overheating of the furnace malfunction of the sensor reaching the protection temperature of the furnace e...

Страница 25: ...n the previously set temperature of the heating water the regulator heats the WUW buffer only up to the pre set temperature of the heating water However setting the priority on WUW heats the WUW buffe...

Страница 26: ...of the burner in the function of maintain the temperature of the heating water is higher than the pre set The chosen power of the burner is a visual value depending on the quality of the applied pelle...

Страница 27: ...03TFT During the first start up of the burner or when detecting a lack of fuel it is necessary to backfill the feeder pipe The FILL function is used in the BURNER menu This function works only in STO...

Страница 28: ...ing the burner s operation time For correct operation of the timer it is necessary to set the current day of the week and the current time in the CLOCK menu The following figure shows a detailed descr...

Страница 29: ...ly switches to BURNING OFF mode and next to the STANDBY mode Lowering the central heating temperature to the minimum temperature set on HEATING menu For each day of the week you can set a separate ope...

Страница 30: ...rder to ensure correct function of time programs Data and time are kept after lack of power for approx 48 hours After this time it is necessary to check the timer adjustments again Parameter s descrip...

Страница 31: ...ption 1 CHOICE LANGUAGE Changing the menu language 2 SOUND Enable disable screen touch sounds 3 TIMER Enable disable timer function 4 DEFAULT SETTINGS Return to factory settings MENU SERVICE Controlle...

Страница 32: ...ice technician have access to them Parameter s description No Parameter name Description 1 BOOT COUNTER Controller booting counter x 2 IGNITION COUNTER Ignitions counter x 3 STB ALARM COUNTER STB alar...

Страница 33: ...ng warranty services are met Terms of acknowledging the warranty claims 1 The warranty is valid only when the user can provide an original invoice or purchase receipt for this device 2 The faulty prod...

Страница 34: ...lf 4 Damages cased during transport due to inappropriate packaging 5 Damages caused by mechanical impact being struck by lightning flooding fire over voltage or other causes independent of the manufac...

Страница 35: ...JUMAR REG 03TFT NOTES 35...

Отзывы: