![JUMAR REG-03TFT Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/jumar/reg-03tft/reg-03tft_instruction-of-installing-and-the-maintenance_2030944010.webp)
JUMAR REG-03TFT
Terminal
No.
Designation
Input/
Output
Description
1
2
BSTB
GND
input
input
Burner feeder sensor connector (bimetal 75
°
C - 90
°
C)
3
4
PL (+)
GND (-)
input
input
Fire sensor connector (opto element)
5
6
x
x
7
L
output
Igniter connector
8
L
output
Air fan connector
9
L
output
Internal feeder connector *
10
L
output
Cleaning system connector *
11
x
12
N
output
Igniter connector
13
N
output
Air fan connector
14
N
output
Internal feeder connector *
15
N
output
Cleaning system connector *
* depend a hardware configuration
Fire sensor (polarity):
CAUTION!!
Bad connection of the sensor causes the weak response of the sensor to the flame/fire.