JUMAR REG-03 Mini Скачать руководство пользователя страница 24

JUMAR REG-03 

Mini

SET TIMER

24H TIMER 

WEEK TIMER

In this group of adjustments, the user has the ability to set the time programs 

determining the burner's operation time. In "

SET MENU

”, the user can select the type 

of timer (

24H

,

 WEEKLY

,

 

°

C+24H, 

°

C+WEEKLY

). Selection of 24H results in activation 

of daily timer (24 hours). Whereas the weekly one causes launching of a weekly timer 

with four  time intervals. Additionally, user can select the timer  function: whether  to 

switch   on/off   the   burner   (

24H

,

  WEEKLY

)   or   whether   the   temperature   should   be 

reduced to minimum temperature (

°

C+24H, 

°

C+WEEKLY

 functions).

EXAMPLES OF TIMER ADJUSTMENTS IN 24H MODE, AS WELL AS IN 

WEEKLY MODE

TIMER 24H

 

 

The figure  below  shows  exemplary   setting  of  burner   operation,  with   a  timer   in   24H 

mode.

The burner works in the following hours: 0-3, 4-7, 8-11, 21-0. Heating is turned off 

between the following hours: 3-4, 7-8 and 11-21.

After selecting the timer adjustments, the first time interval will start pulsating. Pressing 

the 

          

button again will cause switching into another interval.                     

 

buttons 

are   used   for   changing   the   status   (off/blowing/heating)   in   given   hour   interval

The            button causes exiting from settings and saving the changes.

- 24 -

SET

TIMER

MO-TU 02-03

MO-MO 06-23

0-1

ON

0-1

ON

MENU

OK

Содержание REG-03 Mini

Страница 1: ...F THE PELLET S BURNER REG 03 Mini INSTRUCTION OF INSTALLING AND THE MAINTENANCE 1 MENU OK REG 03 Mini MODE INFO JUMAR REG 03 Mini FAN CO CH PUMP STB STB IN BUILD C ROOM THERMOSTAT ALARMS FAN SPEED REG...

Страница 2: ...JUMAR REG 03 Mini 2...

Страница 3: ...ON DIAGRAM 8 OPERATION CONTROLLER 11 BUTTON S DESCRIPTION 11 THE DRIVER S HANDLING 12 MEASURE PANEL DESCRIPTION 13 ALARMS 14 WORKING MODES 15 TEMPERATURE SETTING 17 MENU STRUCTURE 18 SETTINGS TABLES 1...

Страница 4: ...to the maintenance and the safe using of the device Before installing please read the instruction carefully and get to know the functioning of the driver Any questions occur contact with the JUMAR co...

Страница 5: ...others devices of high power without appropriate net filters Avoid putting signal wires in a direct contiguity and in parallel to energetic and powering wires Avoid closeness of remotely controlled d...

Страница 6: ...iac 230V 2A 0 8A Fan triac 230V 2A 0 8A Pump relay 230V 2A 0 8A Protection Temperature build in STB 80 C 400 C Electric external Fuse 4A Inputs Room thermostat Open contact Fire sensor Opto element He...

Страница 7: ...a particular temperature in the room To controller added timer functions now user can set heating time THE PRICIPLE OF WORKING The device s work is based on providing fuel via steering the feeder app...

Страница 8: ...or to network it is necessary to check all the connections carefully One has to take particular note of not placing 230V power supply cables instead of the sensor Improper connection may permanently d...

Страница 9: ...l heating pump connector 13 14 STB STB input input STB fuse connector bimetal 95 C 15 16 CH CH input input Central heating sensor connector 17 18 FIRE FIRE input input Fire sensor connector opto eleme...

Страница 10: ...CH CH Sensor Central heating water sensor CH 3 FEED Burner Sensor The sensor protects the burner against excessive temperature growth Bimetal sensor has to selected according to the burner 4 FIRE Fir...

Страница 11: ...nu or change a parameter s value New value can be accepted by this button Screen change Increase value of temperature Goes up in the settings menu sub menu or increase a value of parameter Decrease va...

Страница 12: ...ntroller show measurement panel The following figure shows an example of the appearance of LCD screens By using the button you can switch to the display visualizing the action of particular burner s e...

Страница 13: ...2 Icon indicating the fan operation 3 If fan working icon will be animated Icon indicating the igniter operation 4 Is displayed alternately with the icon of the feeder Icon indicating the feeder oper...

Страница 14: ...es the burner to stop and switch into damping mode The burner s operation is blocked The display will show the following message STB alarm has to be reseted manually after decreasing the temperature b...

Страница 15: ...left ashes The cleaning function also as a blow down before ignition WORK Heating the boiler up to the set temperature Showing the actual power of the burner PAUSE Sustaining the set temperature if th...

Страница 16: ...ates functions linked to the ignition of the pellet if the particular burner s function requires it The driver carries out three trials of ignition of the pellet The lack of flame may be caused by the...

Страница 17: ...e set value Heating water temperature CH boiler hysteresis activates the burner function If there is no flame in the burner it will be ignited again In the picture below illustrates how change a value...

Страница 18: ...particular group s parameters In order to make changes of the parameters by pressing button To change the values buttons ought to be pressed Press so as to save the new settings In the picture below...

Страница 19: ...in contin 4 FEEDER FILLING SET TIMER PARAMETER NO PARAMETER NAME UNIT SETTING RANGE DEFAULT VALUE 1 TIMERS SETTINGS HOURS 0 23 0 SET CLOCK PARAMETER NO PARAMETER NAME UNIT SETTING RANGE DEFAULT VALUE...

Страница 20: ...ARM 6 SENSOR ALARM 7 AVERAGE CONSUMPTION 8 TOTAL CONSUMPTION Only in V2 0 firmware CAUTION The manufacturer s settings are only the suggestions All values depend on the kind of solid fuel installation...

Страница 21: ...e in the last group and would like to switch lower then the first group will be selected again Similarly when you are in the first group and would like to switch to a higher one you will switch to the...

Страница 22: ...the boiler or ignite the pellets again Setting the hysteresis more than 5 C is reasonable only when heating the central heating buffer 2 CH PUMP TEMPERATURE The threshold temperature of starting the...

Страница 23: ...rner in the function of maintain the temperature of the heating water is higher than the pre set The chosen power of the burner is a visual value depending on the quality of the applied pellet The pow...

Страница 24: ...hould be reduced to minimum temperature C 24H C WEEKLY functions EXAMPLES OF TIMER ADJUSTMENTS IN 24H MODE AS WELL AS IN WEEKLY MODE TIMER 24H The figure below shows exemplary setting of burner operat...

Страница 25: ...is possible to change the hour interval 1 2 into the burner switched off The burner will provide heating between 1 00 AM and 2 00 AM TIMER WEEKLY The figure below shows exemplary setting of burner op...

Страница 26: ...tart Pressing the MENU button again will cause switching to the time of program stop Pressing the MENU button again will cause switching to burner operation mode The UP DOWN button changes the mode to...

Страница 27: ...eter s description No Parameter name Description 1 CURRENT DAY Setting of current day of week 2 CURRENT HOUR Setting of current hour 3 CURRENT MINUTES Setting of current minutes SET MENU In this group...

Страница 28: ...codes only Only device s manufacturer or service technician have access to them Total and average consumption can be reseted by using a code 001 on Set Service menu Parameter s description No Paramete...

Страница 29: ...ing warranty services are met Terms of acknowledging the warranty claims 1 The warranty is valid only when the user can provide an original invoice or purchase receipt for this device 2 The faulty pro...

Страница 30: ...elf 4 Damages cased during transport due to inappropriate packaging 5 Damages caused by mechanical impact being struck by lightning flooding fire over voltage or other causes independent of the manufa...

Страница 31: ...JUMAR REG 03 Mini NOTES 31...

Отзывы: