![JUMAR REG-03 Mini Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/jumar/reg-03-mini/reg-03-mini_installation-and-maintenance-instruction_2030943019.webp)
JUMAR REG-03
Mini
SETTINGS' TABLES
➢
SET HEATING:
PARAMETER
NO.
PARAMETER
NAME
UNIT
SETTING
RANGE
DEFAULT
VALUE
1
CH HYSTERESIS
°C
1 - 30
°C
2°C
2
CH PUMP TEMPERATURE
°C
20 - 80
°C
35°C
➢
SET BURNER:
PARAMETER
NO.
PARAMETER
NAME
UNIT
SETTING
RANGE
DEFAULT
VALUE
1
BURNER POWER (WORK)
kW
10 - 100kW
30kW
2
BURNER POWER (PAUSE)
kW
2 – 9kW
3kW
3
BURNER MODE
---
single/contin
contin
4
FEEDER FILLING
---
---
---
➢
SET TIMER:
PARAMETER
NO.
PARAMETER
NAME
UNIT
SETTING
RANGE
DEFAULT
VALUE
1
TIMERS SETTINGS
HOURS
0 — 23
0
➢
SET CLOCK:
PARAMETER
NO.
PARAMETER
NAME
UNIT
SETTING
RANGE
DEFAULT
VALUE
1
CURRENT DAY
DAY
MO — SU
---
2
CURRENT HOUR
HOUR
00 — 23
---
3
CURRENT MINUTES
MINUTES
00 — 59
---
➢
SET MENU:
PARAMETER
NO.
PARAMETER
NAME
UNIT
SETTING
RANGE
DEFAULT
VALUE
1
CHOICE TIMER MODE
---
24H/WEEK
°
C24H/
°
CWEEK
24H
2
CHOICE LANGUAGE
---
PL/EN/LT/UK
PL
3
FACTORY SETTINGS
---
OK
---
➢
SET SERVICE:
PARAMETER
NO.
PARAMETER
NAME
UNIT
SETTING
RANGE
DEFAULT
VALUE
1
SERVICE CODE
---
---
---
- 19 -