Operator responsibility – Safety instructions 

18 

Information about the used refrigerants 

The

 Regulation (EU) No. 517/2014 on fluorinated greenhouse gases 

applies to all systems 

which contain fluorinated refrigerants and replaces (EC) 842/2006. 

The aim of the Regulation is to protect the environment by reducing emissions of fluorinated 

greenhouse gases. 

Among other things it regulates the emission limits, use and recovery of these substances. It 

also contains requirements for operators of systems which require / contain these substances 

to function. 

 

Under Regulation 517/2014, the operator of a system of this nature has the following duties: 

 

  The operator must ensure that the equipment is checked at regular intervals for leaks. 

  These intervals depend on the CO

2

 equivalent of the system. This is calculated from 

the refrigerant fill volume and type of refrigerant. The CO

2

 equivalent of your system is 

shown on the model plate. 

  The operator undertakes to have maintenance, repair, service, recovery and recycling 

work carried out by certified personnel who have been authorized by JULABO. 

  All such work must be documented. The operator must keep records and archive them 

for at least five years. The records must be submitted to the relevant authority on 

request. 

 

Refer to the text of the Regulation for further information. 

Содержание FT401

Страница 1: ...glish Operating manual Immersion Coolers FT402 FT902 FT903 FT 402 C FT902 C JULABO GmbH 77960 Seelbach Germany Tel 49 7823 51 0 Fax 49 7823 2491 info de julabo com www julabo com 1 950 4620 en V08 06...

Страница 2: ...nual prior to beginning operation Unpacking and inspecting Unpack the immersion cooler and accessories and inspect them for possible transport damage Damage should be reported to the responsible carri...

Страница 3: ...afety notes for the user 21 4 1 Explanation of safety notes 21 4 2 Explanation of other notes 21 4 3 Safety instructions 22 5 Preparations 23 5 1 Installation 23 5 2 Immersion probe Sensor connection...

Страница 4: ...l adapts the cooling supply to the thermal requirements of the bath Electrical connection Connection for Pt100 external sensor for temperature measurement and control Model FT402 is provided with a ha...

Страница 5: ...ation Make sure the product is checked for proper condition regularly depending on the conditions of use Regularly check at least every 2 years the proper condition of the mandatory warning prohibitio...

Страница 6: ...non corroding materials When using hazardous materials or materials that could become hazardous the operator must affix the enclosed safety labels 1 2 to the front of the unit so they are highly visi...

Страница 7: ...ge Therefore only qualified personnel should handle the disposal Valid in EU countries See the current official journal of the European Union WEEE directive Directive of the European Parliament and of...

Страница 8: ...Operator responsibility Safety instructions 8 2 2 EC Declaration of Conformity...

Страница 9: ...Immersion Coolers 9...

Страница 10: ...Operator responsibility Safety instructions 10...

Страница 11: ...mersion Coolers 11 2 3 UKCA Declaration of Conformity UK Office JULABO UK Ltd Unit 7 Casterton Road Business Park Old Great North Road Little Casterton Stamford PE9 4EJ United Kingdom Tel 44 1733 2658...

Страница 12: ...Operator responsibility Safety instructions 12...

Страница 13: ...Immersion Coolers 13 2 3 1 Warranty conditions...

Страница 14: ...user a free extended warranty to 24 months limit to a maximum of 10 000 hours of service A prerequisite for this is that the user registers the device at www julabo com quoting its serial number withi...

Страница 15: ...frigerant 230 V 50 Hz 115 V 60 Hz R452A R404a Electrical connections Pt100 external sensor Pt100 Overall dimensions WxDxH cm 20x30x43 Immersion probe Lxdia cm 12x5 Immersion probe flexible Lxdia cm Co...

Страница 16: ...C 20 10 20 40 80 Medium ethanol kW 0 3 0 27 0 24 0 2 0 07 Cooling compressor 2 stage Refrigerant 230 V 50 Hz 115 V 60 Hz R404A R23 R404A R23 Electrical connections Pt100 external sensor Pt100 Overall...

Страница 17: ...according to IEC 60 529 IP21 The unit corresponds to Class I Overvoltage category II Pollution degree 2 Caution The unit is not for use in explosive environment EMC requirements The device is an ISM d...

Страница 18: ...ation 517 2014 the operator of a system of this nature has the following duties The operator must ensure that the equipment is checked at regular intervals for leaks These intervals depend on the CO2...

Страница 19: ...w Rear view 1 7 8 9 10 FT 402 C 11 12 13 10 A M P 10 A M P 1 Mains power switch illuminated I on off 2 Edit keys increase decrease setting 3 Enter key store 4 LED temperature display 5 Control indicat...

Страница 20: ...it Order No 8 981 003 Pt100 sensor 200x6 mm dia stainless steel 9 Clamp for immersion probe 10 Immersion probe 11 Mains power cable with plug 12 Mains circuit breakers resettable FT402 10 A FT902 FT90...

Страница 21: ...of risk which if it not prevented may result in minor to moderate injuries WARNING This signal word designates a danger with a medium level of risk which if it not prevented may result in death or ser...

Страница 22: ...e connection of the immersion probe Keep the air intake and exhaust grids free of obstructions Maintain a sufficient distance from all surrounding surfaces Do not move the unit from the position where...

Страница 23: ...ant For 0 52 kg of refrigerant R404A 1 m3 of space is required For 0 423 kg of refrigerant R452A 1 m3 of space is required For 0 68 kg of refrigerant R23 1 m3 of space is required The instrument shoul...

Страница 24: ...der No 8 981 003 Connect the Pt100 sensor to the connector Pt100 To prevent the immersion probe A from icing it should be completely immersed into the bath liquid B Important Place the external sensor...

Страница 25: ...voltage specified on the type plate Deviations of 10 are permissible 6 2 Switching on Start Stop Switching on The immersion cooler is turned on and off with the mains switch 1 The unit performs a self...

Страница 26: ...mode This safe operating state is indicated by OFF on the LED temperature display A complete shutdown of the main functional elements is effected simultaneously The values set on the immersion cooler...

Страница 27: ...er can only control the temperature if both the Pt100 sensor and immersion probe are immersed into the same bath fluid Application Cooling a fluid in a vessel If the actual temperature falls below the...

Страница 28: ...down of the compressor is performed The alarm light illuminates and a continuous signal tone sounds The LED temperature display indicates the cause for the alarm in form of a code Press enter to quit...

Страница 29: ...cting cable is electrically connected to the plug housing Pt100 Connector for external Pt100 sensor Pin assignment Pin Signal 1 I 2 U 3 U 4 I The shield of the connecting cable is electrically connect...

Страница 30: ...cooler is designed for continuous operation under normal conditions Periodic maintenance is not required Clean the outside of the unit using a wet cloth and low surface tension water Regularly check...

Страница 31: ...23 51 66 Fax 49 7823 51 99 Service de julabo com When returning the unit Clean the unit in order to avoid any harm to the service personnel Attach a short fault description During transport the unit h...

Отзывы: