![Jula Meec tools 082-208 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/jula/meec-tools-082-208/meec-tools-082-208_operating-instructions-manual_2030472008.webp)
8
ENGLI SH
Read the Operating Instructions carefully before use!
TECHNICAL DATA
Nozzle
1.5 mm
Connection
1/4"
Working pressure
4,0 bar
Air consumption
85-200 l/min
Sound pressure level, LpA
Sound power level, LwA
Vibration level
83 dB(A), K=3 dB
94 dB(A), K=3 dB
<2,5 m/s², K=1,5 m/s²
Always use hearing protection!
OPERATION
1.
Screw the paint container and air hose firmly on the spray gun.
2.
Suitable air pressure depends on the viscosity of the paint and the type of work. 3 to 3.5 bar is
suitable for most applications.
3.
A suitable distance between the spray gun and workpiece is 15-20 cm. Inappropriate distance and
spray patterns produce inferior results.
4.
Adjust the paint flow and air flow knobs.
MAINTENANCE
1.
Steep the paint gun body in clean solvent and brush it clean.
2.
Dismantle the air cap and paint nozzle, dip them in solvent and brush them clean.
3.
Be careful not to damage the holes in the nozzles.
4.
Spray some solvent through the spray gun to clean the paint ducts.
5.
Adjust the needle seal while you squeeze the trigger and check how the paint needle moves. Do
not overtighten.
TROUBLESHOOTING
Fault
Possible cause
Action
Uneven coating
1.
A worn needle seal means that air is
leaking into the paint duct.
2.
The paint connection is loose or damaged.
3.
T
he paint container’s nut is loose, allowing
air to leak in.
1.
Replace the O-ring or
tighten the seal screw.
2.
Tighten or replace.
3.
Tighten.
Thicker on the
sides, thinner in the
middle
1.
The air cap’s square holes are partially
clogged.
2.
Solid containments in the upper part of the
paint nozzle.
1.
Clean the hole. Do not use
metal wire or hard objects.
Pattern
1.
The air cap’s square holes are partially
clogged.
1.
Clean the hole.
Содержание Meec tools 082-208
Страница 10: ......