ENGLISH
101
Important
The plug should never be unplugged from the wall socket during the winter. This is because the heating
cables in the outdoor unit will be switched off, and they are intended to protect the system. If the heat
pump needs to be switched off, use the remote control. Do not pull out the plug.
Pull out the plug from the wall socket if there is a risk of a thunder storm, because lightning can destroy
the system components. Pull out the plug when the heat pump is not going to be used during the summer
for a long period, or if you go away.
Switch off the system and pull out the plug before carrying out any form of maintenance on the system.
Filters and cleaning
The front panel needs to be opened to access the filters. Press in the two white buttons on the short sides
at the same time. Release the panel by unhooking the two fasteners in the middle of the panel.
Lift the panel straight up and remove the filters.
The filters should be cleaned and replaced before each heating season. They should also be cleaned
regularly as long as the system is in use. The filters prevent dust and other particles from penetrating into
the fan and heat exchanger. If the filters get filled with dust the capacity of the system to emit cooling or
heat will be significantly reduced. It is therefore very important to keep the filters clean. We recommend
cleaning the filters at least once a month, more often if necessary, as long as the system is in operation.
Use a vacuum cleaner to remove the dust on the main filter and then rinse under running lukewarm
water, or soak in soapy water for one hour. Rinse the filter and allow to dry before replacing. Never wash
the main filter in a washing machine or in water hotter than 50
0
C. This could deform the filter. The carbon
filter and micro filter should only be vacuum cleaned, or replaced.