– 54 –
1. Connect the connector of material end sensor
(ED) to connector
(CN54 : 4P) of SC-920.
2. Tighten the cord of the material end sensor to-
gether with other cords with cable clip band
attached to the side of the box after passing it
through the cable clamp.
(Caution) 1. Be sure to turn OFF the power be-
fore connecting the connector.
2. For the use of the material end sen-
sor, refer to the Instruction Manual
attached to the material end sensor.
1. Connect the connector of PK70 to connector
(CN39 : 12P) of SC-920.
2. Tighten the cord of PK70 together with other
cords with cable clip band
attached to the
side of the box after passing it through the cable
clamp.
(Caution) Be sure to turn OFF the power before
connecting the connector.
1. Turn ON the power switch with
switch
held pressed.
2. "FL ON" is displayed on indicators
and
with a blip to make the auto
lifter function effective.
3. Turn OFF the power switch, and turn
ON the power switch again to return
to the normal mode.
4. Repeat the operation 1) to 3), and
LED display is turned to (FL OFF).
Then, the function of auto-lifter does
not work.
FL ON : Auto-lifter device becomes effective. Selection of the auto-lifter
FL OFF : Auto-lifter function does not work. (Similarly, the presser foot is not automatically lifted when pro-
grammed stitching is completed.)
Solenoid drive display (+33V)
Air drive display (+24V)
(Caution) 1. To perform re-turning ON of the power, be sure to perform after the time of one second or
more has passed.
(If ON / OFF operation of the power is performed quickly, setting may be not changed
over well.)
2. Auto-lifter is not actuated unless this function is properly selected.
3. When “FL ON” is selected without installing the auto-lifter device, starting is momentarily
delayed at the start of sewing. In addition, be sure to select “FL OFF” when the auto-lifter
is not installed since the touch-back switch may not work.
WARNING :
When the solenoid is used with the air drive setting, the solenoid may be burned out. So, do not
mistake the setting.
When the auto-lifter device (AK) is attached, this function makes the function of auto-lifter work.
6. CONNECTING PROCEDURE OF JUKI OPTIONAL DEVICE
(1) Connection of the material end sensor (ED)
(2) Connection of the pedal of standing-work machine (PK)
(3) Setting of the auto lifter function
device of solenoid drive (+33V) or of air drive (+24V) can be
performed with switch
.
(Changeover is performed to drive power +33V or +24V of CN37.)