70
Input IO
When the head 3 modes are punching
modes, the parameters are valid, and
the IO of the input detection of the
punching device corresponds to the IO
of the punching device.
Delay
(
ms
)
0.000-
100.000
0.000
When the head 3 modes are punching
modes, the delay time is the interval
between "output IO" and "input IO".
Start the output IO
ahead of time(mm)
0.000-
8.000
0.000
The parameter "head 3 mode" is valid
when the punching mode is used.
Before reaching the punching position,
the "output IO" is turned on as many
distances as possible in advance.
Length of punching
bottom feed(mm)
0.000-
50.000
0.000
The head 3 mode is effective when the
punching mode is used, and the length
of the punching base material is
currently used.
Total length of
punching bottoms
0.000-
2000000.0
00
0.000
When the head 3 mode is the punching
mode, it is effective, and the total length
of the punching base material.
The Z axis is used as
a shift line
Yes/No
Yes
Special settings for sewing electric
blankets
Shift line position
0.000-
80.000
0.000
The parameter "Z axis is used as
cycloid" is valid when it is opened, and
the magnitude of the cycloid's
oscillation is large.
Right angle
compensation length
X(mm)
0.00-1.50
0.00
When the inflection point is right angle,
the inflection point moves along the
length of X direction.
Right angle
compensation length
Y(mm)
When the inflection point is right angle,
the inflection point moves along the
length of Y direction.
Frame to Other
Yes/No
No
The head 3 mode is effective when the
parameter is punching mode, and the
"pressing frame" operation of the main
page is automatically changed to