30
-
No.
Item name
Picto-
graph
Input range
Remarks:
S001 Type of pattern
/
Standard pattern /
User pattern
* This data is for display only. To
edit the data, delete the direct
pattern and create a new direct
pattern.
S002 Pattern No.
Standard pattern
:
1 to 51
User pattern
:
1 to 200
* This data is for display only. To
edit the data, delete the direct
pattern and create a new direct
pattern.
S003 X enlargement/
reduction scale/
actual dimen-
sion
When inputting in terms of per-
centage (%): 20 - 200 %
When inputting an actual di-
mension: Within the range of
actual dimensions correspond-
ing to the percentage
Input method (percentage or actu-
al dimension) can be selected by
setting the memory switch U064.
(Initial value: Input in percentage)
S004 Y enlargement/
reduction scale/
actual dimen-
sion
When inputting in terms of per-
centage (%): 20 - 200 %
When inputting an actual di-
mension: Within the range of
actual dimensions correspond-
ing to the percentage
Input method (percentage or actu-
al dimension) can be selected by
setting the memory switch U064.
(Initial value: Input in percentage)
S005 Thread tension
0 to 200
Directly specify the thread tension
with the THREAD TENSION key.
The thread tension cannot be
selected with
▼▲
key.
S006 Sewing speed
400 to 3200
The maximum input range de-
pends on the maximum sewing
speed set with the memory switch
U001.
S007 X travel
amount
− 20 to 20
S008 Y travel
amount
− 20 to 10
S009 2-step stroke
work clamp
stroke height
50 to 90
Display/hide of the stroke height
can be selected using the mem-
ory switch U069. (Initial value:
Hide) When the hide is selected,
the stroke height is not displayed
on the data edit screen.
S010 Position of the
last stitch X
travel amount
− 2.0 to 2.0
Display/hide of the stroke height
can be selected using the mem-
ory switch U070. (Initial value:
Hide) When the hide is selected,
the stroke height is not displayed
on the data edit screen.
S011 Position of the
last stitch Y
travel amount
− 2.0 to 2.0
Display/hide of the stroke height
can be selected using the mem-
ory switch U070. (Initial value:
Hide) When the hide is selected,
the stroke height is not displayed
on the data edit screen.
S012 Comment
The number of characters that
can be input: 14
(2) Listing of item data