35
ENGLISH
W4
The material end sensor does not oper-
ate properly unless this setting is per-
formed.
Change the jumper pin for material end sensor from
+5V to +12V.
(+5V has been set at the time of delivery from the factory.)
(1) Installing the components
1) Install luminescence sensor
1
with screws
2
so
that it is in parallel to the cloth plate.
2) Fix the sensor cord
3
with cord clamp
5
so that it
is not caught with presser lifting lever
4
.
6. Installing the material end sensor
WARNING :
To protect against personal injury due to abrupt start of the machine, conduct maintenance works with
the power turned off.
1
2
3
4
5