– 10 –
Panel cord binding procedure
❶
Remove two setscrews from the presser regulator cover.
Remove the presser regulator cover.
❷
Arrange the panel cord as illustrated in the figure. Then, secure
the cable with a cable clip band.
It is necessary to place the panel cord at a position where the cord
does not come in contact with the mechanical parts.
❸
Align the notch in the cover with the panel cord.
❹
Fix the presser regulator cover with the setscrews.
CAUTION
Turn OFF the power switch.
Always must be disconnected plug from socket-outlet.
❺
❶
❷
❸
❹
❻
Installing the eye protection cover
1. Place eye protection cover
❷
and washer
❸
in the written order
on eye protection cover mounting plate
❶
and fix them with set
-
screw
❹
.
2. Install eye protection cover mounting plate
❶
on frame
❻
with
two setscrews
❺
.
DANGER
Be sure to install the eye protection cover since the cover protects
eyes from being injured by a fragment of a broken needle.
CAUTION
Turn OFF the power switch.
Always must be disconnected plug from socket-outlet.
❶
❸
❷
❹