![JUKI EF08HD Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/juki/ef08hd/ef08hd_instruction-manual_2029433005.webp)
ENGLISH
3
1 Introduction
This manual mainly explains how to attach or detach a tape reel for EF08HD.
For detailed functions, refer to "Instruction Manual" in "Instruction Manual CD version" attached to a mounter and also "EF08HD
Instruction Manual. "
2 Name of each part
25
23
24
28
27
1
4
3
2
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
26
3 Operation panel section
Name of operation
LED
display
Button operation
Explanation of operation
Feed pitch setting
02 / 04
Press
■
switch button twice
Press
▲
switch button or
▼
switch button to
change a feed pitch
Press
■
switch button twice
To switch a feed pitch to 2 mm and 4 mm
Initialization 0H
Press
■
switch and
▼
switch at the same time
To put it into states that can be produced
Initialization completion state
cancellation
Press and hold
■
switch button long
To cancel initialization state
Normal rotation pitch feed
Press and hold
▲
switch button long
To feed a tape by a pitch
Reverse rotation pitch feed
Press and hold
▼
switch button long
To reversely feed a tape by a pitch
Operation stop
Press
■
switch button short
To stop feed operation and initialization operation
Error reset
E
Press
■
switch button short
To cancel error display
Operation lane change
Press
switch button alone
To be able to change operation effective lane
(between L and R)
Button operation Press a switch button short:: for less than one second
Press a switch button long: for one second or more
Press a button twice: the same switch button for less than one second and two times in sequence
Press a button at the same time: two switch buttons at the same time
4 Specification
Product code
EF08HD/EF08HD (IS)
Feed pitch
2 and 4
mm
Color of lever
Blue
Number of occupied positions
1
Outside dimensions
Entire length: 911 mm, height: 455 mm,
and width: 17 mm(A reel support is attached.)
Mass 3.0
kg
Power supply
Supplied from a mounter
Component transporting method
Motor-driven
Power-supply voltage
DC 24V
Allowable current
2.1A
Tape size
Available two 8 mm tapes
(0603 or bigger component)
Tape types
Paper and embossed tapes
Emboss tape conditions
Applicable component emboss width : 4.3 mm or less
Applicable component
emboss depth : 3.5 mm or less
Operation environmental
conditions during operation
Temperature: 10
℃
to 35
℃
, humidity: 30 to 80% RH (No condensation), altitude: 1,000 m or less
Accuracy guarantee
temperature
Temperature: 20
℃
to 25
℃
Noise 57.7
dB(A)
Excessive voltage class
Class 1 (IEC60664-1): Excessive voltage is supplied from the circuit whose voltage is limited to a low level (such as a secondary low
voltage circuit)
Environmental pollution level
Level 3: Environment whose pollution is worse than that of the normal environment (such as a manufacturing plant)
* Use components whose size and tape specifications conform to JIS C0806-3:1999 and IEC 60286-3:2007.
No.
Description
No.
Description
No.
Description
1
Upper cover (L/R)
11
Lock release lever
21
Tape loading slot (L lane)
2
Sprocket wheel (L/R)
12
Front liner block assy
22
Reel support guide
3
Cover tape U guide
13
RFID tag (for the IS specification only)
23
Reel support L assy
4
Tensioner arm (L/R)
14
Slide rail
24
Reel support arm
5
Idler arm (L/R)
15
X guide pin R
25
Tail guide
6
Grip chamber frame
16
Lock section (Bank clamp section)
26
Reel hook
7 Operation
panel
17 Connector
27
PP
cap
8
Storage space for PP cap and Tape support
18
Bottom guide block
28
Tape support
9
Chamber lid
19
Rating plate
10
Tape loading slot (R lane)
20
Revision label