List of memory switch data
1) Level 1
It can be set when a mode screen for the operator level has been displayed.
No.
Item
Setting range
Unit
Initial value
SMS
SSH
FMS
FSH SMS CE SSH CS FMS CE FSH CE
U001
Soft-start function
The initial value differs with the machine head. (0: OFF)
0 to 9
Stitch
0
0
0
0
0
0
0
0
U007
Bobbin thread count-down unit
0: 10 stitches / 1: 15 stitches / 2: 20 stitches
0 to 2
-
0
0
0
0
0
0
0
0
U008
Reverse feed stitching speed
Set the sewing speed for a multi-layer stitching and a reverse
feed stitching.
The number of revolutions set with this memory switch is given
precedence even if it is lower than the lowest speed by pedal.
150 to 3000
sti/min
1900
1900
1900
1900
1900
1900
1900
1900
U013
Bobbin thread count stop function
0: Sewing machine start prohibition function is disabled even
when the counter completes counting (negative value).
1: When the counter completes counting, the sewing machine
start after thread trimming is prohibited.
2: When the counter completes counting, the sewing machine
temporarily stops and the start of sewing machine after thread
trimming is prohibited.
* Note that the prohibition function is disabled in the case the
initial value of counter is 0 (zero).
0 to 2
-
0
0
0
0
0
0
0
0
U014
Sewing count function
1: Automatic sewing counter / 2: Sewing counter switch input
1 to 2
-
1
1
1
1
1
1
1
1
U021
Presser foot lift when the pedal is in its neutral position
0: Disabled / 1: Enabled
0 to 1
-
0
0
0
0
0
0
0
0
U025
Operation after manual turning (thread trimming)
This memory switch is used for setting the thread trimmer
operation after the sewing machine has moved from its upper/
lower stop position by manual turning of handwheel.
0: Permitted / 1: Prohibited
0 to 1
-
1
1
1
1
1
1
1
1
– 105 –