Fault
1701649 • 2019/04
JUDO JPF-A
21
7
Fault
A fault is indicated by the red control lamp lighting up.
Deleting the fault indication: Pull the power supply unit out of the socket and after about 5
seconds plug it in again..
Fault
Possible cause Remedy
Continuous sig-
nal tone
Fault no. ...
Cause of fault
Signal transmit-
ter sounds.
DIP switch was
incorrectly set.
Correct the settings of the DIP switch! (see Chapter
Setting the backwashing interval and Potential-free
•
Pull the mains plug out of the socket.
•
Inform the installer or the closest customer ser-
vice point.
•
If water escapes, close shut-off valves.
The red "Fault"
indicator light
flashes; the sig-
nal transmitter
sounds a horn.
Electrical or
mechanical
defect.
•
Delete fault indication!
•
Restart backwashing by manual triggering.
If the fault occurs again:
•
Pull the mains plug out of the socket.
•
Inform the installer or the closest customer ser-
vice point.
•
If water escapes, close shut-off valves.
All three LED
flash.
Maintenance
required.
(see Chapter Warranty and maintenance)
Backwash
valve is not fully
closed.
Backwash water
continues run-
ning.
Dirt in backwash
valve.
Water flow
decreases.
Sieve clogged.
Restart backwashing by manual triggering.
If the backwash water runs on:
•
Inform the installer or the closest customer ser-
vice point.
There are leaks
in the filter bowl.
Damaged seals.
Filter bowl
becomes
clouded.
Hairline cracks
on the filter
bowl.
Filter bowl was
exposed to high
temperatures or
solvents.
•
Pull the power supply unit out of the socket.
•
Inform the installer or the closest customer ser-
vice point.
•
If water escapes, close shut-off valves. Have the
filter bowl replaced immediately.
Troubleshooting
Содержание PROFIMAT JPF-A 1 1/2"
Страница 12: ...Installation 12 JUDO JPF A 1701649 2019 04 4 4 1 Drainage options for the backwash water JPF A 1 JPF A 1 2...
Страница 28: ...Technical data 28 JUDO JPF A 1701649 2019 04 9 4 Circuit diagram for device control...
Страница 29: ...Technical data 1701649 2019 04 JUDO JPF A 29 Circuit diagram for device control with potential free relays...
Страница 30: ...Technical data 30 JUDO JPF A 1701649 2019 04 9 5 Spare parts JPF A 1...
Страница 33: ...Technical data 1701649 2019 04 JUDO JPF A 33 JPF A 1 2...
Страница 36: ...Technical data 36 JUDO JPF A 1701649 2019 04 JPF A 2 4...