5

Type

Type

Backwash Protective Filter

JUDO PROFI 2½" (DN65) - 4" (DN100)

Abbreviated Designation:

JPF 2½" (DN65) - 4" (DN100)

Design Types

Technical Data

The following applies for all the models of
the device:

Pressure loss when clean (after back-
washing): 3 psi (20 kPa) at the water flow
rate (nominal flow rate) given in the table.

Maximum ambient temperature and
water temperature: 30 °C (86 °F).

The water to be filtered must possess
quality of drinking water!

Threaded connection to DIN 2999.

Flange connection according to DIN 2633.

The nominal pressure denotes the pressure
class, according to which the filter must fulfill
the requirements to DIN EN 13443-1 and
DIN 19628. The maximum operating pres-
sure is lower, in order to ensure the optimum
function of the filter.

Installed dimensions

A = Installation length
B = unit width
C = Height above pipe centre
D = Height below pipe centre
F = Connection dimension waste water

Model

Pipe 
connection

Order 

No.

JPF 2½" (DN65)

2½"

8010138

JPF 3" (DN80)

3"

8010117

JPF 4" (DN100)

4"

8010139

Nominal Pressure

Model

Operating
Pressure

Nominal 
Pressure

JPF 2½" 
(DN65)

22 - 150 psi
(150 - 1000 kPa)

PN 16

JPF 3" (DN80), 
4" (DN100)

22 - 150 psi
(150 - 1000 kPa)

PN 10

Water flow rate

Model

Water flow rate for a pres-
sure loss of 3 psi (20 kPa) 

with clean sieve insert

1)

JPF 2½" (DN65)

119 gpm (27.0 m³/h)

JPF 3" (DN80)

220 gpm (50.0 m³/h)

JPF 4" (DN100)

308 gpm (70.0 m³/h)

1)

Data concerning the water flow rate are

valid for drinking water. The maximum water
flow rate for more polluted water is lower,
depending on the mesh size If so, a larger
dimension has to be chosen.

Fig. 4: Installed dimensions e.g.: JPF 3" (DN80)

All dimensions in inch (mm) (see fig. 4)

Model

A

B

C

D

F

JPF 2½" 
(DN65)

9.4 

(240)

7.3 

(185)

13.1 
(332)

6.3 

(159)

¾"

JPF 3"
(DN80)

12.5 
(320)

9.1 
(232)

15.8 
(402)

6.5 

(166)

¾"

JPF 4"
(DN100)

12.5 
(320)

9.1 
(232)

16.2
(412)

6.9 

(176)

¾"

Содержание PROFI JPF 2 1/2 DN65

Страница 1: ...uctions and safety information before installing and putting the unit into service These Instructions must always be issued to the owner user Installation and Operating Instructions JUDO PROFI 2 DN65...

Страница 2: ...t can be installed into all drinking water pipes usual in the trade in each flow direc tion To ensure easy operation and maintenance the indicated minimum distances have to be observed The installatio...

Страница 3: ...bove 150 psi 1000 kPa the pressure reduction valve should be fitted in front of the Back wash Protective Filter see fig 3 If the operating pressure is above 150 psi 1000 kPa this may result in defects...

Страница 4: ...Doing this it is prevented that the sieve cloth is damaged by a too strong pres suring of the suction tube At the same time the rinse water consumption is reduced With a flush valve opened to one hun...

Страница 5: ...stallation length B unit width C Height above pipe centre D Height below pipe centre F Connection dimension waste water Model Pipe connection Order No JPF 2 DN65 2 8010138 JPF 3 DN80 3 8010117 JPF 4 D...

Страница 6: ...m Designation Recommended average replacement interval for wearing parts Piece s 2 Order No Piece s 3 4 Order No 1 Lid of handwheel 1 1607152 1 1607152 2 Countersunk screw M5x12 1 1607454 1 1607454 3...

Страница 7: ...120135 16 Suction Pipe complete 1 2607135 1 2010029 17 Filter Screen MW 0 10 mm 0 004 inch 1 2010380 1 2010376 18 O ring 1 1607110 2 1607110 19 Flush pipe JPF 3 1 2010039 19 Flush pipe JPF 4 1 2010044...

Страница 8: ...g All rights are reserved for modifications as a result of technical progress or further developments Claims with regard to models or products are excluded 1701746 2009 08 Installed by JUDO Water Trea...

Отзывы: