![Judo JUKOMAT-LONGLIFE-AT Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/judo/jukomat-longlife-at/jukomat-longlife-at_installation-and-operating-instructions-manual_2029222020.webp)
Servicing
7
Servicing
7.1
Cleaning
CAUTION
Do not use household cleaning
agents to clean the outside of the
device, but only use clear water to
avoid embrittlement of the plastic.
7.2
Warranty and maintenance
Prerequisite for obtaining the statutory war-
ranty claim is regular backwashing (see
chapter 4.3). The DIN EN 13443-1 pre-
scribes that backwashing must take place
every six months. JUDO, however, recom-
mends compliance with the information in
chapter 4.3.1 Backwashing interval.
Moreover, the set outlet pressure must be
checked yearly on the downstream pressure
gauge, in particular, both with zero flow and
at peak flow (high water drawing level). If
necessary, the outlet pressure setting must
be readjusted.
To ensure the process operates success-
fully as long as possible, regular inspec-
tion and routine servicing of the device are
essential. Where home automation is con-
cerned, this is governed by DIN EN 806-5.
We recommend the conclusion of a main-
tenance contract, which is the best way
to ensure a good operating function, even
beyond the warranty period. The skilled
tradesmen or the factory customer service
are suitable partners for regular mainte-
nance work and the supply of consumables
and wear materials as well as for possible
repairs.
The maintenance sticker on the device
serves as a reminder of the next mainte-
nance date and should be marked by the
installer after installation.
20
JUDO JUKOMAT-LF-AT
1701431 • 2022/01
Содержание JUKOMAT-LONGLIFE-AT
Страница 12: ...Installation 3 4 1 Drainage options for the backwash water 12 JUDO JUKOMAT LF AT 1701431 2022 01...
Страница 24: ...Technical data 8 3 Spare parts JUKOMAT LF AT 1 24 JUDO JUKOMAT LF AT 1701431 2022 01...
Страница 27: ...Technical data JUKOMAT LF AT 1 2 1701431 2022 01 JUDO JUKOMAT LF AT 27...