background image

Installation

INFO_NO_HEADER

If the installation is twisted, a func-

tioning of the device is not possible.

1

2

Fig. 3:

Rotary flange fitting

1

Profile flange seal

2

Flow direction arrow

3.3

Installation of the device

CAUTION

If no bypass valve is installed, a

shut-off valve must be installed

upstream and downstream of the

unit in order to interrupt the water

supply during installation, mainte-

nance, repair or malfunction of the

device.
Install the device in a vertical

position (± 5°); the connection

for waste water from backwash-

ing must be directed downwards.

Otherwise, water may escape and

cause water damage.
For the installation of the device

in domestic water piping, only use

the supplied built-in rotary flange

(see chapter 3.2).
The flange surface of the rotary

flange fitting must be upright!
For proper sealing the profile of

the profile flange seal must point

towards the rotary flange fitting

(see Figure 3: Rotary flange fitting,

page 10).

Fig. 4:

Attach and engage appliance

1

Insert screws

2

Turn clockwise to engage screws

10

JUDO JUKOMAT-LF-AT  

1701431 • 2022/01

Содержание JUKOMAT-LONGLIFE-AT

Страница 1: ...Installation and operating instructions JUDO JUKOMAT LONGLIFE AT Automatic domestic water station 2 Valid for EU countries and Switzerland Language English Read before use and store...

Страница 2: ...ng even in excerpt form is only per mitted with special approval Dear customers Thank you for the confidence you have shown in us by purchasing this prod uct You have purchased a state of the art devi...

Страница 3: ...Warning lights 13 4 2 Setting the downstream pres sure 13 4 3 Cleaning of the sieve insert backwashing 13 4 4 Conversions changes 16 4 5 Battery replacement 16 4 6 Maintenance repair spare parts 17 4...

Страница 4: ...plicable national regulations INFO_NO_HEADER Particles that are smaller than the mesh size of the filter supplied and materials causing cloudiness cannot be filtered out of the water 1 2 Application l...

Страница 5: ...ec tion e g floor drain in compliance with DIN 1986 must be provided In order to ensure safe drinking water hygiene a free discharge of the waste water acc to DIN EN 1717 must be ensured The pipe must...

Страница 6: ...ational use the device must be depressurised If this is ignored the result may be uncon trolled escape of water resulting in water damage to the building home If the device is removed due to an inter...

Страница 7: ...ve insert The adhering residues are visible from outside through the transparent filter bowl JUKOMAT LONGLIFE AT 1 The fil ter bowl is visible through the viewing slot of the UV protection screen The...

Страница 8: ...el of the pressure reducer 3 Pressure reducer 4 Rotary flange fitting 5 Downstream pressure gauge 6 UV protection screen slideable JUKOMAT LF AT 1 7 Filter bowl 8 Backwashing automatic component 9 Bac...

Страница 9: ...ctive filters The device bears the DIN DVGW mark as proof of certification 3 Installation CAUTION The device may only be installed by qualified technical personnel Installation of the device upstream...

Страница 10: ...ice Install the device in a vertical position 5 the connection for waste water from backwash ing must be directed downwards Otherwise water may escape and cause water damage For the installation of th...

Страница 11: ...giene a free dis charge of the waste water acc to DIN EN 1717 must be ensured Prior to plugging in the device ensure that the wastewater con nection is functional The drain must be large enough so tha...

Страница 12: ...Installation 3 4 1 Drainage options for the backwash water 12 JUDO JUKOMAT LF AT 1701431 2022 01...

Страница 13: ...counter clockwise pressure reduction 4 Open a drawing point behind the device for a short time This results in a pres sure relief and the set downstream pressure can be read off from the downstream pr...

Страница 14: ...rding to DIN EN 13443 1 backwashing the device is required at the latest every six months To keep the functioning of the appliance as smoothly as possible the longest backwash interval is set by the m...

Страница 15: ...he control electronics of the automatic system To do this attach the cable lug of the short cable strand to the pin with the inscription cor responding to the desired time interval see Figure 8 A B C...

Страница 16: ...the unit to the power supply This reduces the mains voltage for operating the electronics to a harmless low voltage of 24 V 4 5 Battery replacement CAUTION Only use 9 V block batteries of alka line t...

Страница 17: ...WARNING A defective backflow preventer must be replaced immediately The backflow preventer may only be replaced by trained technical personnel The testing screw at the inlet connection of the built in...

Страница 18: ...by qualified technical personnel Switching voltage maximum 24 V Amperage maximum 1 A 5 1 Potential free message Devices with potential free signal relay can transmit fault indication messages a b c z...

Страница 19: ...n warn ing lights no backwash ing will be triggered Battery is empty or incorrect bat tery type 1 Pull the mains plug out of the socket 2 Insert new 9V Alkaline battery 3 Plug in the plug again There...

Страница 20: ...k flow high water drawing level If necessary the outlet pressure setting must be readjusted To ensure the process operates success fully as long as possible regular inspec tion and routine servicing o...

Страница 21: ...ow acc to DIN EN 1567 2 3 m h 3 6 m h 5 8 m h 9 1 m h 14 0 m h Settable downstream pressure 1 5 bar 6 bar 1 5 bar 6 bar 1 5 bar 6 bar 1 5 bar 6 bar 1 5 bar 6 bar Factory setting of downstream pres sur...

Страница 22: ...1 JUKOMAT LF AT 1 JUKOMAT LF AT 1 JUKOMAT LF AT 2 A 180 195 230 301 335 A1 175 195 B 130 130 130 108 108 C 158 158 158 181 181 D 317 317 317 402 402 E 190 190 195 226 234 F 82 82 87 118 126 G 50 50 5...

Страница 23: ...e water connector mid to pipe mid G Waste water connection size G1 Waste water connection size alt 8 2 Accessories Cable for external fault signal order no 2170437 Expansion QUICKSET JQR order no 8250...

Страница 24: ...Technical data 8 3 Spare parts JUKOMAT LF AT 1 24 JUDO JUKOMAT LF AT 1701431 2022 01...

Страница 25: ...9 30 31 32 1 8170244 589 1 Pressure reducer cover 1 2 Cover Basic housing JUKO LF AT 1 2 Cover Basic housing JUKO LF AT 1 1 2 Cover Basic housing JUKO LF AT 1 1 3 Display button 1 4 Hexagon socket hea...

Страница 26: ...head self tapping screw 3 9x13 2 27 Motor 1 28 Motor cover 1 29 Electronic control unit 1 30 9 V block battery alkaline 1 31 Power supply unit 1 32 Automatic housing 1 33 O ring 6 07 1 3 1 34 Hose co...

Страница 27: ...Technical data JUKOMAT LF AT 1 2 1701431 2022 01 JUDO JUKOMAT LF AT 27...

Страница 28: ...gon socket head screw set with 4 pcs 1 2170654 29 2 Countersunk screw M5x8 1 3 Washer A 8 4 1 4 Handwheel of the pressure reducer 1 5 O ring 84x4 2 6 O ring 38x4 1 7 Hexagon nut M8 4 8 Basic housing p...

Страница 29: ...31 Handwheel 1 Table 5 Spare parts list JUKOMAT LF AT 1 2 1 AU Accounting unit articles without an accounting unit are only available as part of a set Replacement interval 3 years 4 years 9 Disposal P...

Страница 30: ...interference immunity EN 61000 6 2 EN 61000 6 3 Harmonized Standards Safety of power transformers power sup plies reactors and similar products EN 61558 1 The observance of the mentioned directives an...

Страница 31: ...aintenance log 11 Maintenance log Product designation Automatic domestic water station Order number Serial number Date Work activities performed Company Signa ture 1701431 2022 01 JUDO JUKOMAT LF AT 3...

Страница 32: ...online ch judo online ch BENELUX JUDO Wasseraufbereitung GmbH Filiaal Filiale Benelux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Phone 32 0 24 60 12 88 Fax 32 0 24 61 18 85 E mail inf...

Отзывы: