background image

Installation and operating instructions

JUDO JULDOS 4 - 25

Dosing pump

Valid for: EU countries and Switzerland

Language: English

Read before use and store!

Содержание JJD 10

Страница 1: ...Installation and operating instructions JUDO JULDOS 4 25 Dosing pump Valid for EU countries and Switzerland Language English Read before use and store...

Страница 2: ...nting even in excerpt form is only per mitted with special approval Dear customers Thank you for the confidence you have shown in us by purchasing this prod uct You have purchased a state of the art d...

Страница 3: ...dosing quantity 17 5 2 Selection of the appropriate JUL mineral solution tablets 18 5 3 Refilling the mineral solution container 18 5 4 Protection against third party access 19 5 5 Conversions change...

Страница 4: ...s Above water pressures of 10 bar a pressure reducer must be installed upstream of the filter 5 bar installation of a pressure reducer upstream of the device is recommended The water pressure must not...

Страница 5: ...alfunctions of the device For JJD 4 The pipe must be able to safely support the device weight see chapter 9 If necessary the pipes must be provided with additional fastenings or support For JJD 4 Alwa...

Страница 6: ...age In the event of temporary removal of the device protect the flange surfaces against damage to ensure proper sealing protect the device from dirt so as not to impair drinking water hygiene store th...

Страница 7: ...on and operating instructions 2 2 Function description Dosing pump During drawing of water water of the drink ing water system flows through the water meter The output signal of the incorporated flow...

Страница 8: ...Rotary flange fitting 3 Control unit cover 4 Dosing container Fig 2 Function description JJD 10 25 1 Power supply unit 2 Rotary flange fitting 3 Control unit cover 4 Dosing container 5 Water meter Th...

Страница 9: ...tes in drinking water are adhered to 2 3 Remote monitoring The device can be integrated in building control systems see chapter 6 2 4 Materials used The materials used are resistant to the physical ch...

Страница 10: ...the device upstream of the water meter is forbidden 3 1 Requirements for the place of installation The installation room must be dry and free from frost The ambient temperature must not exceed 30 C I...

Страница 11: ...rotary flange fitting must be vertical i e point forwards The rotary flange fitting must be fitted so that it is free from mechanical stress or strain Oth erwise mechanical damage to the pipe or the r...

Страница 12: ...g in water escaping Fig 4 Align the seal profile with the rotary flange fitting 3 5 1 Installing JJD 4 The dosing pump is connected directly as a unit in combination with the water meter Do not undo t...

Страница 13: ...vice is not damaged or strained 3 5 2 Install JJD 4 with wall mount ing If the pipes are too low or too high or if there is not enough space the JJD 4 mod els can also be mounted on the wall sepa rate...

Страница 14: ...EADER Minimum clearance from the bot tom edge of the wall mounting to the ground or the underlying pipes JJD 4 approx 550 mm 6 Fit the dosing pump in the wall mount ing The top lug of the wall mountin...

Страница 15: ...les on the rotary flange fit ting see Figure 11 Fig 11 Place and engage 1 Feed screws through 2 Turn clockwise to engage 2 Turn the water meter in a clockwise direction up to the stop see Figure 11 an...

Страница 16: ...ion nut with an open ended spanner and screw off Refitting the dosing hose Cut off the dosing hose just after the indentation and install according to the manual INFO_NO_HEADER The indentation in the...

Страница 17: ...en com missioning the device after mainte nance work 5 Operation 5 1 Setting the dosing quantity Three different settings can be selected for the dosing of JUL mineral solution into the drinking water...

Страница 18: ...ening system JUL W Tabs 1 2 Mixed installation 2 and 3 JUL H Tabs 1 Table 1 JUL mineral solution available types 1 Tabs tablet form 2 Not available for Switzerland 5 2 1 JUL mineral tablets For model...

Страница 19: ...no mineral solution tablets are available the empty dosing container must be filled with water and con nected to prevent drying out of the pump head 5 4 Protection against third party access The devic...

Страница 20: ...ypass valve 3 Arrange for a technical service provider to remove the device The device must be bled and flushed prior to restarting Open the stopcock or the bypass valve Open a tap downstream of the d...

Страница 21: ...cing of the device are essential Where home automation is con cerned this is governed by DIN EN 806 5 We recommend the conclusion of a main tenance contract which is the best way to ensure a good oper...

Страница 22: ...after installation 7 3 Function check If the device is functioning correctly the yellow warning light flashes with every piston stroke during drawing of water the JUL mineral solution decreases in th...

Страница 23: ...socket 2 Inform the installer or the closest customer service point The yellow warning light comes on and an audible signal is output Dosing container empty Fill mineral solution container see chapte...

Страница 24: ...and ambient temperature max 30 C Threaded connection according to DIN EN 10226 1 Power connection 230 V AC 50 Hz Power consumption Operation 3 W 3 W 3 W Dosing power consumption 6 W 12 W 24 W Operati...

Страница 25: ...nting installation dimensions Minimum installation height from the floor to the rotary flange fitting JJD 4 590 mm Table 2 Wall mount ing installation dimen sions for JJD 4 see also chapter 3 5 2 1703...

Страница 26: ...ons Fig 18 JJD 4 installation dimensions with integrated water meter Fig 19 JJD 4 installation dimensions with external water meter Fig 20 JJD 10 installation dimensions Fig 21 Installation dimensions...

Страница 27: ...e rotary flange fitting C Height above the pipe middle resp device height D Height below the pipe middle E Installation depth up to the pipe middle K Water meter width K1 Water meter width to the midd...

Страница 28: ...ection of two devices e g filter and dosing pump JJD 4 10 JUDO Bypass valve JQX order no 8735210 Mineral tablet dissolving device order no 8130100 Recommendation From approximately 14 dH water hard ne...

Страница 29: ...the local recycling system To protect environment old appliances must not be disposed of with household waste Instead use the local collection and return points which are committed to free and environ...

Страница 30: ...Spare parts 11 Spare parts JJD 4 30 JUDO JULDOS 1703383 2022 10...

Страница 31: ...Synchronous motor with frame JJD 4 1 2120255 251 5 Gear console 1 6 Hexagonal nut M3 2 7 Gear eccentric 1 8 Piston rod 1 9 Small shim 1 10 Sheet metal screw 2 9 19 1 11 Pump holder 1 12 Power supply u...

Страница 32: ...ushing 1 34 Water meter impeller 1 35 Water meter housing insert 1 36 O ring 60 3 1 37 Hexagonal nut M6 4 38 Water meter housing 1 2120098 125 39 Injection nozzle hose 1 40 O ring 9 2 1 41 Injection n...

Страница 33: ...Spare parts JJD 10 1703383 2022 10 JUDO JULDOS 33...

Страница 34: ...ounter washer 1 4 Piston rod 1 5 Eccentric 1 6 Support ring 1 7 JJD 10 synchronous motor 1 8 Disc 4 3 2 9 Hexagonal nut M4 2 10 Cylinder screw M4 10 2 11 Pump holder 1 2609301 167 12 Power supply unit...

Страница 35: ...1 33 O ring 60 3 1 34 Water meter housing 1 2120099 125 35 Hexagonal nut M6 4 36 Profile flange gasket 1 37 Cylinder screw M6 25 4 38 Hexagonal nut M5 6 39 Injection nozzle hose 1 40 O ring 9 2 1 41...

Страница 36: ...Spare parts JJD 25 36 JUDO JULDOS 1703383 2022 10...

Страница 37: ...sher 1 4 Piston rod 1 5 Eccentric 1 6 Support ring 1 7 JJD 25 synchronous motor 1 8 Hexagonal nut M4 2 9 Disc 4 3 2 10 Cylinder screw M4 10 2 11 Pump holder 1 2609301 167 12 Power supply unit 24 V AC...

Страница 38: ...25 1 2120143 49 37 Water meter inspection glass 1 2120190 115 38 O ring 105 3 1 39 Water meter brass insert 1 2120188 245 40 O ring 88 3 1 41 Water meter housing 1 42 Injection nozzle hose 1 43 O ring...

Страница 39: ...nterference immunity EN 61000 6 2 EN 61000 6 3 Harmonized Standards Safety of power transformers power sup plies reactors and similar products EN 61558 1 The observance of the mentioned directives and...

Страница 40: ...udo online ch judo online ch BENELUX JUDO Wasseraufbereitung GmbH Filiaal Filiale Benelux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Phone 32 0 24 60 12 88 Fax 32 0 24 61 18 85 E mail...