Installation

The flushing water must be discharged into
a firmly mounted drain.

Flushing water discharge options

Ensure that the wastewater con-
nection functions before plugging
the power supply unit into the
socket.

Fig. 6:

Flushing water discharge options

> 6 inch
   150 mm

> 1 inch
   (20 mm)

Содержание BIOSTAT 25 TGA

Страница 1: ...rmation before installing and putting the unit into service These instructions must always be issued to the owner user Installation and operating instructions JUDO BIOSTAT 25 TGA Water treatment devic...

Страница 2: ...Winnenden All rights reserved Reprints even of extracts are only permitted with special written approval Dear Customer thank you for the confidence you have shown in us by purchasing this unit With t...

Страница 3: ...which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving ante...

Страница 4: ...missioning 13 5 2 Setting the cleaning interval 14 5 3 Description of its function 14 5 4 Control lamps manual pushbuttons 16 5 5 Cleaning flushing 17 6 Maintenance 17 6 1 Demand for maintenance 17 6...

Страница 5: ...e may only be carried out by personnel authorized by the manufacturer who are capable of fulfilling the instructions given in the installation and operating instructions and the country specific presc...

Страница 6: ...and mechanical effects danger to persons and the environment due to leaks Refrain from any unsafe working methods Failure to comply with this instruction manual and the safety information can not onl...

Страница 7: ...g the water treatment device outside the use limitations given in the instruction manual The water treatment device is only to be used in a technically perfect condition for their intended use safely...

Страница 8: ...the power supply a short circuit can also occur In this case there is a risk of people suffering an electric shock Electrical devices equip ment located near the water treatment device must therefore...

Страница 9: ...ected in the drinking water All materials are hygienically and physiologically safe Plastics fulfill the official guideline of the German Federal Environmental Agency as well as the work sheet W 270 i...

Страница 10: ...an occur 4 2 2 Power supply ATTENTION see chapter Safety information and dangers due to non compliance A permanent power supply that is not connected to a light switch must be avai lable If the water...

Страница 11: ...water escaping This can cause damage due to water to the house and its in stallations 4 3 Discharging the flushing water An adequately dimensioned wastewater connection e g floor drain according to D...

Страница 12: ...er must be discharged into a firmly mounted drain Flushing water discharge options Ensure that the wastewater con nection functions before plugging the power supply unit into the socket Fig 6 Flushing...

Страница 13: ...y has been connected the electrical circuit performs a self check of all the functions and parameters stored in the electronics Following a successful check all control lamps flashes four times As soo...

Страница 14: ...correct settings the circuit responds with an acoustic signal tone see chapter Fault Remount the panelling of the water treat ment device see chapter Mounting of the panelling 5 3 Description of its f...

Страница 15: ...he elec trodes Dissolved calcium in the form of calcium carbonate crystals is then deposited on the cathode the circular stainless steel brushes On cleaning these crystals of calcium carbonate are thr...

Страница 16: ...low LED 1 Operation Conditioning Permanent green light The water treat ment device is ready for use Green light flashing Water treatment is taking place LED 2 Cleaning flushing Permanent green light A...

Страница 17: ...nd for maintenance LED 3 flashes 3 years after commissioning or the latest maintenance of the water treat ment device At a water consumption of over 85 850 gal 325 m per year this time frame reduces B...

Страница 18: ...er flushing is then not possible 6 4 Mounting of the panelling Dismantling Withdraw the upper inferior clamping fixture Carefully pull apart the right and the left panel parts by the handle cavities o...

Страница 19: ...a distri butor or to a properly authorised local disposal return point 6 6 Modifications changes spare parts ATTENTION see chapter Safety information and dangers due to non compliance Only original sp...

Страница 20: ...contact with and be discharged into the drinking water when the water treatment device is switched back on The health of people who drink dirty water is at risk Store the water treatment device in fr...

Страница 21: ...the socket Remove the panelling see chapter Mounting of the panelling Check the cable connections reconnecting each plug and socket connection which is loose Remount the panelling Plug the power suppl...

Страница 22: ...e claims it is necessary in accordance with DIN 1988 section 8 that depending on the individual water consumption a visual inspection of the device has to be effected every 03 to 06 months and that th...

Страница 23: ...that the water treatment device must fulfil the requirements accord ing to W 510 The maximum operating pres sure is lower in order to ensure the optimal function of the water treatment device Installa...

Страница 24: ...por tionally the water with a mineral solution JUL Mineral solutions JUL contain active compo nents which create the conditions in which a homogeneous protective coating can be formed in the system of...

Страница 25: ...JUDO BIOSTAT 25 TGA 25 Spare parts BIOSTAT 25 TGA 11 Spare parts BIOSTAT 25 TGA...

Страница 26: ...0199 2 9 Hexagonal nut M6 4 1633145 1 10 Backflow preventer 1 1 1610287 29 11 Profiled flange seal 1 1200218 5 12 Upper part 1 2210290 210 13 O ring 10x3 1 1120332 2 14 Panelling 1 1140114 72 15 Round...

Страница 27: ...5 Spherical valve 1 2210311 24 206 Tapping screw C2 9x19 2 1609174 1 207 Flat head screw M3x10 1 1650381 1 208 Cheese head screw M3x10 3 1650144 1 209 Motor bracket 1 1120590 19 210 Gear motor complet...

Страница 28: ...the heating backwashing filter and automatic heating feed station for fulfilment of DIN EN 1717 JUDO PROMI domestic water station Backwash protective filter with JUDO PROFI PLUS technology pressure re...

Отзывы: